Bus-Off when CAN-FD ports are not connected

29 Oct 2025

It article describes how missing CAN bus termination causes signal distortion, leading the device to detect a “bus off” error condition.

 

APPLICABLE PRODUCTS

Ixxat Mobilizer, Ixxat CANnector

 

ISSUE / QUESTION / SYMPTOM

Why do I get a bus-off when the CAN-FD ports are not connected?  

 

POSSIBLE CAUSES / ANSWER

When a bit is sent to a port to which no CAN cable (and therefore no device) and no bus termination resistor are connected, the device signals "bus off". This is due to the lack of termination in this case, which shortens the transmitted recessive bit so much that the device can no longer recognize it as such. The problem does not occur with correct termination.