Parker SSD previously supplied OEM branded Red Lion HMIs. As of 2019, they are no longer supplying these HMIs.
Converting DSI8000 and DSI3 files to Crimson files.
The Parker SSD software contained the 890-RTNX serial driver that was previously not supported by Crimson. As of Crimson 3.1 build 3114 (releasing November/December 2019), the 890-RTNX driver will be available in Crimson. In order to use this driver, a device that supports Crimson 3.1 will be required.
Crimson 3.0 does not support the monochrome units, and therefore cannot import monochrome files, so they will first need to be converted to a color HMI.
Extract the DSI800 to C2.zip file.
Rename the Parker SSD file to convert.dsi.
Place the file into the folder extracted in step 1.
Run the batch file.
Allow administrative access.
The converted.cd2 file is now ready for use.
Extract the DSI3 to C3.zip file.
Rename the Parker SSD file to convert.ds3.
Place the file into the folder extracted in step 1.
Run the batch file.
Allow administrative access.
The converted.cd3 file is now ready for use.
It is the customer's responsibility to review the advice provided herein and its applicability to the system. Red Lion makes no representation about specific knowledge of the customer's system or the specific performance of the system. Red Lion is not responsible for any damage to equipment or connected systems. The use of this document is at your own risk. Red Lion standard product warranty applies.
If you have any questions or trouble contact HMS Technical Support by clicking here.