Filter

Loading...
Loading...
Loading...
7 results
Product
Bosch Commercial & VRF systems to Modbus RTU Interface
Item number: INMBSACA001I000

INMBSACA001I000

Document
User Manual

No action is needed. 4.2 Modbus Registers for INMBSACA001I000 All registers are type “16-bit unsigned Holding Register” and use the standard Modbus big endian notation., Intesis ® INMBSACA⁎⁎⁎I000 User Manual v1.7 EN © HMS Industrial Networks S.L.U - All rights reserved This information is subject to change without notice URL https://www.intesis.com 10 / 24 ▪ 0: Closed (Default Value) ▪ 1: Open Register Address (protocol address) Register Address (PLC address) R/W Description 7 8 R/W INMBSACA001I000 Disablement 4 ▪ 0: INMBSACA001I000 enabled (Default) ▪ 1: INMBSACA001I000 disabled 8 9 R/W Remote Control Disablement 4,5 ▪ 0: Remote enabled (Default Value) ▪ 1: Remote disabled 9 10 R/W AC unit Operation Time 4 ▪ 0..65535 (hours)., In order to overcome this limitation and enable the usage of an external temperature sensor (i.e. from Modbus side), INMBSACA001I000 applies the following mechanism (only if “external temperature’s reference” is being used): o After a couple of values have been entered in the “AC unit external temperature’s reference” (register 22/23) and “AC unit temperature set point” (register 4/5), INMBSACA001I000 is going to estimate the chosen temperature differences (e.g. if a “temperature setpoint (register 4/5)” of 22°C, and an “external temperature reference (register 22/23)” of 20°C are entered, INMBSACA001I000 will assume that the user is demanding a +2°C increase in temperature)., If we follow the last example, if INMBSACA001I000 receives a new temperature´s value coming from the indoor unit of 25°C, INMBSACA001I000 will automatically adjust the temperature setpoint required of the AC indoor unit to 25°C + 2°C = 27°C)., This value means that no external temperature reference is being provided through INMBSACA001I000.

Document
Intesis HVAC gateways for Bosch

., 2 Binary Inputs INWMPUNI001I000 Connect to: IR Port 1 Indoor Unit IN770AIR***O000 INKNXACA001I000 Connect to: X/Y terminals Connect to: X/Y/E terminals 4/16/64 Indoor Units 1 Indoor Unit IN770AIR***O000 Connect to: X/Y terminals 4/16/64 Indoor Units IN770AIR***O000 IN770AIR***O000 INMBSACA001I000 Connect to: X/Y terminals Connect to: X/Y terminals Connect to: X/Y terminals 4/16/64 Indoor Units 4/16/64 Indoor Units 1 Indoor Unit IN485UNI001I100 Connect to: IR Port 1 Indoor Unit IN485UNI001I100 Connect to: IR Port 1 Indoor Unit INWFIUNI001I000 Connect to: IR Port 1 I.U., 1 Binary Input Connection to the Bosch indoor units Connection to the Bosch outdoor units 21 21 21 21 Connection to the XYE bus Indoor unit Owned by HMS Industrial Networks, Intesis® is a registered trademark in the European Union and is trademarked in the rest of the world., Other marks and IN485UNI001I100 INKNXUNI001I200 INWMPUNI001I000 INWFIUNI001I000 INMBSACA001I000 INKNXACA001I000 IN770AIR***O000 Outdoor Unit Connection to the XYE bus Indoor Units IR

Document
UKPSTI Certification

INBACHIT064O000 INBACMHI001R100 INBACMID001I100 INBACMID004I000 INBACPAN001R100 INBACPAN016O000 INBACPAN064O000 INBACPAN128O000 INBACSAM001R100 INBACSAM004O000 INBACSAM008O000 INBACSAM016O000 INBACSAM064O000 INBACTOS001R100 INKNXACA001I000 INKNXACA016I000 INKNXACA064I000 INKNXDAI001I000 INKNXDAI001I100 INKNXDAI001R000 INKNXDAI001R100 INKNXFGL001I000 INKNXFGL001R000 INKNXFGL016O000 INKNXHAI008C000 INKNXHAI016C000 INKNXHAI064C000 INKNXHIS001R000 INKNXHIS016O000 INKNXHIS064O000 INKNXHIT001A000 INKNXHIT001R000 INKNXHIT016O000 INKNXHIT064O000 INKNXLGE001R000 INKNXLGE016O000 INKNXLGE064O000 INKNXMHI001R000 INKNXMID001I000 INKNXMID016I000 INKNXMID064I000 INKNXMIT001I000 INKNXMIT001I100 INKNXMIT015C000 INKNXMIT100C000 INKNXPAN001A000 INKNXPAN001I000 INKNXPAN001R000 INKNXPAN016O000 INKNXPAN064O000 INKNXSAM004O000 INKNXSAM008O000 INKNXSAM016O000 INKNXSAM064O000 INKNXTOS001R000 INKNXTOS016O000 INKNXTOS064O000 INKNXUNI001I000 INLUTDAI001R000 INMBSACA001I000

Kb
How to check if my climatization system is compatible with Intesis products?

AC Interfaces & AC Cloud Control - AC (INBACMID001I100, IN485FGL001I000, IN485DAI001I000, INBACDAI001I000, IN485PAN001I000, INBACPAN001I000, INMBSPAN001I100, INMBSPAN001A000, INMBSMIT001I000, INMBSMID001I000, INMBSMID004I000, INMBSMID008I000, INMBSMID032I000, INMBSDAI001I000, INMBSACA001I000, INMBSACA004I000, INMBSACA008I000, INMBSACA032I000, INKNXPAN001I000, INKNXPAN001A000, INKNXMIT001I100, INKNXMIT001I000,INKNXMID001I000, INKNXMID016I000, INKNXMID064I000, INKNXHIT001A000, INKNXFGL001I000, INKNXDAI001I100, INKNXDAI001I000, INKNXACA001I000, INKNXACA016I000, INKNXACA064I000, INWMPPAN001I000, INWMPMHI001I000, INWMPMIT001I000, INWMPFGL001I000, INWMPDAI001I000, INWFIPAN001I000, INWFIMHI001I000, INWFIFGL001I000, INWFIDAI001I000).

Document
Installation Guide

EIA485 A+ B- X Y AC Unit SW3 SW4 SW1 1 2 3 4 SW1* 1 2 3 4 SW4 1 2 3 4 5 6 7 8 SW3 Configuración Modo: AUTO/DRY/ventilación AUTO, velocidades del ventilador Mode configuration: AUTO/DRY/fan AUTO, fan speeds *SW1 is configurable only in case of INMBSACA001I000, not in case of INMBSACA004I000/ INMBSACA008I000/ INMBSACA032I000 You should leave the switches in Default position in this last case.

Document
CE Declaration of Conformity

Address: Milà i Fontanals, 7 08700 Igualada SPAIN Product: Type: RS485 Bus Adaptor for Air Conditioner integration IS-RC5-MBS-1 Order Code(s): INMBSMID001I000, INMBSMID004I000, INMBSMID008I000, INMBSMID032I000 INMBSSAM001R000, INMBSACA001I000, INMBSACA004I000, INMBSACA008I000, INMBSACA032I000 The products are in accordance with the following Directives Number: 2014/30/EU Directive 2014/30/EC of the European Parliament and the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to electromagnetic compatibility.