AB7301-B, Anybus X-gateway – CANopen Master – PROFIBUS SlaveAB7301-BThe Anybus X-gateway CANopen Master to PROFIBUS Slave enables you to connect any CANopen Master device or equipment to PROFIBUS control systems., It can be used when there is no existing CANopen control system., Anybus gateways ensure reliable, secure, high-speed data transfers between different industrial networks while being easy to use.Reach new marketsNo PLC card slot neededSlim hardware design3-year warrantyTarget new markets using different protocols without needing to change your hardware or software, thereby decreasing your time to market and development costs.The gateway does not use a card slot in the control system, leaving room for other equipment.The gateway is designed for IP20 and DIN-rail mounting, enabling you to install it with ease, close to connected devices, thereby reducing wiring requirements.The gateway is designed to be robust and long-lasting.
Anybus X-gateway CANopen enables any PLC to communicate with lithium ion batteries., ALM series lithium-ion secondary battery The ALM series brings high performance, high output, and quick charging., It has best-in-class battery life and can be used even in harsh industrial environments, while also providing high safety., The ALM12V35i series, which has an internal BMS (Battery Management System), can check the internal state of the battery and is very suitable for AGVs and robots., By using CANopen and connecting to a master device such as a PLC via Anybus X-gateway CANopen, it is possible to enable communcation between the battery and the PLC., Supports 10 industrial networksEtherCAT (AB7300) EtherNet/IP (AB7306)Modbus-TCP (AB7308) PROFIINET IO (AB7307)PROFINET IRT (AB7329) CANopen (AB7304) ControlNet (AB7303) DeviceNet (AB7302)Modbus RTU (AB7305) PROFIBUS (AB7301) The ALM series are available via NEC distribution channels., Lithium-ion Batteries
AB7301 www.anybus.com Module Front Side View Bottom View Accessories Checklist The following items are required for installaƟon: CANopen: • ACM CANopen configuraƟon tool (available at www.anybus.com) • CANopen adapter for configuraƟon tool (not included) • CANopen cable (not included) • EDS file, available at www.anybus.com PROFIBUS Interface: • PROFIBUS configuraƟon tool (not included) • PROFIBUS cable • GSD File, available at www.anybus.com Installation and Startup Summary • Select baud rate and an unused node address for the interface., • Restart the module after the CANopen interface has been configured, LED Indicators A B 1 5 6 9 CANopen Connector Pin no., Power: A. +24 V DC B., Pin no Description 1 Shield 3 B Line 4 RTS 5 GND Bus * 6 +5 V OUT * 8 A Line Casing PE 2, 7, 9 (not connected) * Pins 5 and 6 are used for bus termination.
Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Product Change Notification Dear Partner, Anybus appreciates your daily involvement and your long-term loyalty., The products will continue to be offered but no further product enhancement, documentation, development, or conformance testing will be done., Lifecycle policy: https://www.anybus.com/support/anybus-product-life-cycle _______________________________ Magnus Rönn Field Application Engineer Anybus Gateways Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Appendix Article number Product Description AB7001 Anybus Communicator DeviceNet AB7003 Anybus Communicator CANopen AB7006 Anybus Communicator ControlNet AB7008 Anybus Communicator CC-Link AB7010 Anybus Communicator Modbus-RTU AB7077 Anybus Communicator CC-Link IE Field Network AB7078 Anybus Communicator RS232/422/485 - PROFINET IRT AB7079 Anybus Communicator RS232/422/485 - IIoT AB7300 Anybus X-gateway CANopen Master-EtherCAT Slave AB7301 Anybus X-gateway CANopen Master-PROFIBUS DP-V1 Slave AB7302 Anybus X-gateway CANopen Master-DeviceNet Slave AB7303 Anybus X-gateway CANopen, 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB7514 Anybus X-gateway PROFINET IRT Slave-ControlNet Slave AB7515 Anybus X-gateway PROFINET IRT Slave-FIPIO Slave AB7519 Anybus X-gateway PROFINET IRT Slave-PROFINET IRT Slave AB7550 Anybus X-gateway PROFIBUS DP-V1 Master - IIoT AB7551 Anybus X-gateway DeviceNet Master - IIoT AB7553 Anybus X-gateway Ethernet/IP Master - IIoT AB7554 Anybus X-gateway Ethernet/IP Slave - IIoT AB7555 Anybus X-gateway Modbus TCP Slave - IIoT AB7556 Anybus X-gateway IIoT-EtherCAT Slave AB7557 Anybus X-gateway CC-Link IE Field Slave - IIoT AB7558 Anybus X-gateway IIoT-PROFIBUS DP-V0 Slave AB7559 Anybus X-gateway IIoT-DeviceNet Slave AB7560 Anybus X-gateway IIoT-CANopen Slave AB7561 Anybus X-gateway IIoT-Modbus RTU Slave AB7562 Anybus X-gateway IIoT-CC-Link Slave AB7564 Anybus X-gateway IIoT-ControlNet Slave AB7570 Anybus X-gateway IIoT-PROFINET IRT, CC-Link IE Field Network Slave EtherCAT Slave AB7963 Anybus X-gateway CC-Link IE Field Network Slave CANopen Slave AB7964 Anybus X-gateway CC-Link IE Field Network Slave Modbus-RTU Slave AB7985 Anybus X-gateway PROFIBUS DP-V0 Master- PROFINET IRT Fiber Optic Slave AB9071 Anybus PROFIBUS to .NET Bridge AB9077 Anybus PROFINET to .NET Bridge AB9078 Anybus Ethernet/IP to .NET Bridge AB9079 Anybus EtherCAT to .NET Bridge HMS-EN2MB-R EtherNet/IP to Modbus-TCP Linking Device HMS-EN2PB-R EtherNet/IP to PROFIBUS Linking Device HMS-EN2SE-R EtherNet/IP to Serial Linking Device