ABC3013-A, Anybus Communicator – Serial Master to PROFINET IO-DeviceABC3013-AThe Anybus Communicator Serial Master to PROFINET IO-Device enables you to connect any RS-232/485 device or equipment to PROFINET control systems., Anybus Communicators ensure reliable, secure, and high-speed data transfers between different industrial networks., Thanks to our intuitive web-based user interface, they're also incredibly easy to use.Intuitive user interfaceCybersecurityHigh performanceOptimized hardware designUse the intuitive web-based user interface to easily configure the Communicator via the drag-and-drop functionality or to analyze live data, export log files, and generate support packages.The secure boot protects against malware, while a security switch locks configurations to prevent unauthorized changes., Ports used in production are disabled to add another layer of security.Powered by the award-winning NP40 network processor and high-end components, the Communicator meets the constantly growing demand for more data to be transferred faster.The Communicator has forward-facing ports and is designed for IP20 and DIN-rail mounting, enabling you to install it with ease, close to connected devices, thereby reducing wiring requirements.modbusrtu;profinet;serial, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus, Anybus Communicator – Serial Master to PROFINET IO-Device
ChangeLog - ABC3013 ABC3013 - 1.08.01 Added support for PROFINET Legacy mode Category Description Comment Bug fix Remove the unused "Representation" for the Checksum Removed the unused "Representation" field of the Checksum frame object., Table of Contents ABC3013 - 1.08.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.07.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.06.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ABC3013 - 1.05.03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ABC3013 - 1.04.02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., ChangeLog - ABC3013 2 HMS Industrial Networks Improveme nt Add support for checksum destination representation., ABC3013 - 1.06.01 Updated to be conform with PROFINET 2.43.1.2 Category Description Comment Bug fix Incorrect LED timing., to be executed once after gateway start New feature Update mode "Trigger" Allows the user to user data as trigger to execute transactions New feature Added ADD and XOR checksums Allows the user to use ADD and XOR checksums and one’s and two’s complement on all checksums types ChangeLog - ABC3013 2023-07-18 7 HMS Industrial Networks, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus
ChangeLog - ABC3013 ABC3013 - 1.10.02 Added possiblity to change order of nodes Category Description Comment Bug fix Byte swapping sometimes not applied Fixed bug where byte swap was not always effective., ABC3013 - 1.09.02 Category Description Comment Bug fix Don’t mix code and data., ChangeLog - ABC3013 2 HMS Industrial Networks Bug fix IO-size reported for unplugged modules., ABC3013 - 1.06.01 Updated to be conform with PROFINET 2.43.1.2 Category Description Comment Bug fix Incorrect LED timing., New feature Update mode "Trigger" Allows the user to user data as trigger to execute transactions New feature Added ADD and XOR checksums Allows the user to use ADD and XOR checksums and one’s and two’s complement on all checksums types ChangeLog - ABC3013 2024-10-22 7 HMS Industrial Networks, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus
ChangeLog - ABC3013 ABC3013 - 1.05.03 Support hardware with either Broadcom and Texas PHY Category Description Comment Bug fix Buffer overflow was possible due to faulty check of PROFINET station name Fixed bug that could cause the product to go FATAL when validating the PROFINET station name Bug fix Update DCPUCR to provide better error responses Instead of silently dropping DCP requests for unknown or invalid options or suboptions an adequate error response is provided Bug fix Possible NULL pointer access in timer handling Increased stability under extreme interrupt load Bug fix APIData record (Index 0xF8210) includes empty API The APIData record now only contains API:s where one or more modules are plugged Bug fix ACD state could be stuck in conflict even after IP is recovered Fixed bug that could keep the Ethernet connection in conflicted state after Automatic Conflict Detection (checking if IP-address is already taken) was resolved Bug fix PROFINET station name, restricted to lower case letters Removes the risk for the user to enter unallowed capital letters in PROFINET station name Bug fix Navigation bar and mobile mode Navigation bar in web-gui is now automatically hidden on navigation in mobile mode Improvement Let CPU sleep during NULL tasks Reduces the power consumtion of the product ABC3013 - 1.04.02 Category Description Comment Bug fix Disabled timeout = 0 was not allowed during import Allows the user to import a configuration with timeout = 0 without issues ABC3013 - 1.04.01 Category Description Comment Bug fix Full-duplex RS232 communication was not working in some HDL-releases Full-duplex for RS232 is now working in all HDL-releases Table of Contents ABC3013 - 1.05.03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.04.02 . . . . . . ., . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.04.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.03.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ABC3013 - 1.02.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ABC3013 - 1.01.02 . . . . . . . . . . . . . . . . . . . . . . . . . ., . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ABC3013 - 1.00.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ChangeLog - ABC3013 1 HMS Industrial Networks New feature Disabled timeout = 0 (checkbox in gui) Allows the user to disable timeout using a checkbox, leading to set the node always online New feature Process data monitor Allows the user to monitor the traffic between the serial and slave network in both directions including byte swap / endian conversion ABC3013 - 1.03.01 Category Description Comment Bug fix RS485 driver remains active up to 1 character after end of frame RS485 driver remains active up to 1 character after end of frame, causing collision if a modbus slave, gateway start New feature Update mode "Trigger" Allows the user to user data as trigger to execute transactions New feature Added ADD and XOR checksums Allows the user to use ADD and XOR checksums and one’s and two’s complement on all checksums types ChangeLog - ABC3013 4 HMS Industrial Networks, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus
ChangeLog - ABC3013 ABC3013 - 1.09.02 Category Description Comment Bug fix Don’t mix code and data., Bug fix Unable to access "Transaction templates" Fixed access issue to 'Transaction templates' Table of Contents ABC3013 - 1.09.02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.08.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.07.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ABC3013 - 1.06.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ABC3013 - 1.05.03 . . . . . . . . . . . . . . . . . . . ., A previous fix optimizing the alarm queue left gaps in the sequence number series when deleting alarms fr ChangeLog - ABC3013 2 HMS Industrial Networks Bug fix Increment serial number with new fragments in request/response., ABC3013 - 1.06.01 Updated to be conform with PROFINET 2.43.1.2 Category Description Comment Bug fix Incorrect LED timing., ChangeLog - ABC3013 2024-05-17 3 HMS Industrial Networks Bug fix Fixed Modbus to return exceptions in the order they where detected., ab0afe683b6442e380bc7f7ba77b9ce9, Anybus
ChangeLog - ABC3013 ABC3013 - 1.07.01 Added support for: Large serial frame, large variable data object, start / end characters, bugfixes Category Description Comment Bug fix Module could enter fatal during re-configuring., Table of Contents ABC3013 - 1.07.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABC3013 - 1.06.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ABC3013 - 1.05.03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ABC3013 - 1.04.02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ABC3013 - 1.04.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., . . . . . . . . . . . . . . . . . . . . . . . . . 4 ABC3013 - 1.03.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ABC3013 - 1.02.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ABC3013 - 1.01.02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ABC3013 - 1.00.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ChangeLog - ABC3013 2023-05-11 1 HMS Industrial Networks Bug fix Use consecutive numbers for Alarm Sequence Numbers., ChangeLog - ABC3013 2 HMS Industrial Networks ABC3013 - 1.06.01 Updated to be conform with PROFINET 2.43.1.2 Category Description Comment Bug fix Incorrect LED timing., to be executed once after gateway start New feature Update mode "Trigger" Allows the user to user data as trigger to execute transactions New feature Added ADD and XOR checksums Allows the user to use ADD and XOR checksums and one’s and two’s complement on all checksums types ChangeLog - ABC3013 2023-05-11 7 HMS Industrial Networks, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus
This article describes how to assign the same name to PROFINET network when a new gateway is used to replace the old one. , APPLICABLE PRODUCTS ABxxxx(with PROFINET network) such as: AB7013, ABC3013, AB7317, AB7658, AB7649, ABC4013...... , QUESTION Using a new gateway to replace the old one, they have the same configuration and IP address, Why can't establish the communication between the new gateway and PLC in PROFINET network? , ANSWER In addition to use the same configuration as the old gateway, the new gateway needs to be assigned the same name to the PROFINET network as the old one., (1) Use Ethernet cable to connect PC and gateway PROFINET port (2) Run PRONETA software (3) Select the gateway device (4) Set the same name as the old gateway Tips: 1)If you don't know the old gateway PROFINET name, you could get it by PRONETA as described above. 2)In some control system, you need use the same port as the old gateway if there was 2 ports in PROFINET side of gateway. , ab0afe683b6442e380bc7f7ba77b9ce9
This article describes how to upgrade firmware for Anybus Communicator. , APPLICABLE PRODUCTS ABC3xxxx,ABC4xxxx Example:ABC3000,ABC3090,ABC3013,ABC4090,ABC4091,ABC4012 PRE-REQUISITES Download the latest firmware from HMS official website: 1., Enter the product artical number such as ABC3000, click the product picture on the right side. 3., The Communicator configuration port default IP address is 192.168.0.10 Set the PC a static IP address within the same IP address range as the Communicator IP address. 2., Open a web browser, click to select the Address bar and enter the Communicator IP address: 192.168.0.10. , How to upgrade firmware for Anybus Communicator, ab0afe683b6442e380bc7f7ba77b9ce9
This article describes the difference about Address format in Anybus Communicator transaction setting. , APPLICABLE PRODUCTS ABC3013, ABC3061, ABC3000, ABC3007, ABC3028 QUESTION There are 4 options in Address format, what is the difference between them? , ANSWER The 4 options in Address format represent the register address format, no matter which one is selected, it represents the same register address, but the format displayed in the attributes on the right of the transacton is different., For example, in the Read Holding Registers transaction, set the starting register address to 0: (1) Address format select "Address (0,1,2,...) ", the transaction starting register address is displayed as "Address 0", They all mean the first holding register, and you can use any one as you like. , What‘s the difference about Address format in Anybus Communicator transaction setting, ab0afe683b6442e380bc7f7ba77b9ce9
Date of Publication: 2021-10-01 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Product Change Notification Dear Partner, Anybus appreciates your daily involvement and your long-term loyalty., Article number Description Replacement product AB7000 AB7007 AB7013 AB7028 AB7072 Anybus Communicator PROFIBUS DP-V0 Anybus Communicator EtherNet/IP Anybus Communicator PROFINET IO Anybus Communicator Ethernet Modbus-TCP Anybus Communicator EtherNet/IP or Modbus-TCP 2-port ABC3000 ABC3007 / ABC3090 ABC3013 / ABC3090 ABC3028 / ABC3090 ABC3007 / ABC3028 / ABC3090 Key Milestones 2022-01-01 2023-01-01 2023-09-01 2024-01-01 The Communicator Classic products listed above will be replaced by the new Communicator and enter lifecycle phase limited., Prices will be raised, lead times will increase, and no further enhancements will be done., The products listed above will enter lifecycle phase Exit Last time buy for the products listed above The products listed above will be Obsolete Reason for Change The new Communicator has been developed to meet customer requirements for enhanced performance, usability and security and will replace the products listed above., Lifecycle policy: https://www.anybus.com/support/anybus-product-life-cycle _______________________________ Fredrik Brynolf Product Manager Anybus Gateways, PCN 211001 - Anybus Communicators Lifecycle statement LTB, ab0afe683b6442e380bc7f7ba77b9ce9
This Article shows you how to find gateway serial number for ABCxxxx. , APPLICABLE PRODUCTS All ABCxxxx products., Such as:ABC3000,ABC3090,ABC3013,ABC4090,ABC4091,ABC4012, ABC3113 PRE-REQUISITES There are 3 ways to find it. , IN THIS ARTICLE Method 1., How to find gateway serial number (ABCxxxx), ab0afe683b6442e380bc7f7ba77b9ce9
This article introduces how to import configuration file to ABC3xxx serial gateway and what things need to be noted., APPLICABLE PRODUCTS The gateway of ABC3xxx with serial interface. , PRE-REQUISITES The ABC3xxx series serial gateway allows configuration files to be imported into each other even if the gateway model is different., For example, if the configuration file of ABC3013 (PROFINET ->serial) is imported into ABC3007 (EtherNet/IP ->serial), the serial communication configuration can be imported normally, while the upper network configuration (PROFINET \ EtherNet/IP...) will not be imported., When the imported gateway configuration file does not match the actual gateway model, a network mismatch prompt will appear., Notes of importing configuration file to ABC3xxx serial gateway, ab0afe683b6442e380bc7f7ba77b9ce9
Now that’s possible with legacy mode for PROFINET, PROFIBUS and Modbus TCP! , No need to change GSDML/GSD file and you can continue to use Anybus addressing mode on Modbus TCP., Hereby we inform you about the release of updated firmware and user interface for Anybus Communicator. , Affected products: ABC3000, Serial Master – PROFIBUS IO Device ABC3013, Serial Master – PROFINET IO Device ABC3028, Serial Master – Modbus TCP Server ABC3090, Serial Master – Common Ethernet ABC4011, EtherNet/IP adapter - Modbus TCP server ABC4013, PROFINET IO device - EtherNet/IP adapter ABC4014, EtherNet/IP adapter - PROFIBUS DP device ABC4016, Modbus TCP server - EtherCAT slave ABC4017, PROFINET IO device - Modbus TCP server ABC4018, Modbus TCP server - PROFIBUS DP device ABC4020, PROFINET IO device - EtherCAT slave ABC4021, EtherCAT slave - PROFIBUS DP device ABC4023, PROFINET IO device - PROFIBUS DP device ABC4090, Common ethernet - Common ethernet ABC4091, Common ethernet - PROFIBUS DP device Description: The release(s) contains the following features and bugfixes: Availability: Firmware package(s) will be available on the product support page along with a change log., Updated manuals will be available soon. , ab0afe683b6442e380bc7f7ba77b9ce9
616dde05-22ce-6706-92f4-ff00001bbfd4---ABC3013-01---, ab0afe683b6442e380bc7f7ba77b9ce9
Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the product is used correctly in their specific application and that the application meets all performance and safety requirements including any applicable laws, regulations, codes and standards., NOTE As an alternative, you can set a static IP address within the same IP address range as the Communicator IP address on the computer accessing the Communicator built-in web interface., Te c h n i cal Specifications Article identification ABC3013 Configuration connector RJ45 Communication connector RJ45 x 2 Serial connector 7-pin screw connector Power connector 3-pin screw connector Power supply 12-30 VDC, Reverse voltage protection and short circuit protection Power consumption Typical: 90 mA @ 24 V (2.2 W) Max: 3 W Storage temperature -40 to +85 °C Operating temperature -25 to +70 °C Humidity EN 600068-2-78: Damp heat, +40°C, 93% humidity for 4 days EN 60068-2-30: Damp heat, +25°C – +55°C, 95% RH, 2 cycles Vibration See datasheet Housing material Plastic, See datasheet for details Protection class IP20 Product weight 150 g Dimensions 27 x 144 x 98 mm (W x H x D) with connectors included Mounting DIN-rail Anybus ® Communicator ™ - PROFINET to Modbus RTU/Serial Technical Data Page 24 of 28 SP2954 Version 1.12 8., switch is locked Red, solid N/A FATAL event N/A N/A Red, one flash N/A Station name not set., N/A N/A Red, two flash N/A IP address not set N/A N/A Red, three flash N/A Expected Identification differs from Real Identification N/A N/A Red, flashing Invalid configuration One or more connections timed out All nodes are offline N/A Green/Red, flashing Power up self-test/ Firmware update/ Firmware recovery N/A N/A N/A Fatal Error and Exception Error Fatal error: A fatal error causes the Communicator firmware application to crash in an uncontrolled manner., Startup Guide - Anybus Communicator PROFINET, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus
-C YES 63d9e2de-0aeb-4f1f-a6e0-b1898c5e95ba AB4460-B YES 457e6a4d-8b4b-418a-be11-b6ac313442a8 AB4468-C NO AB4474-B NO AB4483-C NO AB4500-C NO AB4554-C YES 4ac7ac58-3d19-4a7a-9f7f-caf7c52f77b0 AB4571-C NO AB4582-B YES cb91fcb6-4838-4f7b-8e9b-a05206c21f5e AB4611-C YES af8674e4-fad9-42f5-a1f8-69a3db22a8ee AB4613-B NO AB4622-C YES d5cccb01-53eb-4ba7-8ec4-e23b18a6883f AB4643-B NO AB4648-C YES 66617109-53b9-4368-99d4-1107e88c5ecb AB4698-C YES d137df4b-56ce-4b72-9dfe-f47ee1c3b3b0 AB4720-B NO AB4735-C NO AB4739-C NO AB4742-C YES c356f60b-2fb1-4aaf-bb3b-7866b41e048f AB4780-C YES d53fd21b-675b-4551-aa58-59c4c499af46 AB4804-C NO AB4805-B YES 29765699-0ef0-4be1-b050-b29c2baf540f AB4806-C YES 9325d034-4ca0-4b99-9bb3-8af505e32c83 AB4807-C NO AB4817-C YES 21ddfa41-93df-42c3-befd-8eb25db4f28f AB4863-C YES 5e6b6b7a-95b1-43db-8c55-24a7a899e893 AB4864-C NO AB5105-B YES 148a5370-be40-45ab-8570-b5810af0ef55 AB5051-B YES a6301d40-464b-487a-a9fa-b133f182ef88 AB5055-B YES d3fb9d34, -49ee-9977-8fc955a2959c AB6455-B NO AB6476-B YES 5a5257c7-27fb-48f4-8c96-1fb3b6f07488 AB6484-B YES 914bec82-6a6d-4e6c-b3cd-c8694b6155d5 AB6487-B YES d9e4f04e-7617-4d4b-8507-58d6bfaf0c49 AB6506-B NO AB6507-B NO AB6511-C NO AB6518-B YES 73a30ade-8946-4331-b575-e1580f96398f AB6526-B YES 1a8be2f7-c996-4cff-8df7-828463d81165 AB6600-C YES d99df5b7-25f2-4fe6-a119-980e6f62adfc AB6601-C YES 0b290aab-e272-4f37-81f0-cb5f1552bd35 AB6602-C NO AB6603-E NO AB6604-C NO AB6604-D NO AB6604-D-158 NO AB6604-E NO AB6605-C NO AB6605-D NO AB6605-D-205 NO AB6605-E NO AB6606-C NO AB6607-C NO AB6607-D-224 NO AB6607-E NO AB6609-B NO AB6610-C NO AB6610-D NO AB6610-E NO AB6611-E NO AB6612-E NO AB6613-C YES f62f55f7-a4b1-48e8-9c74-9c35d819fdba AB6634-E NO AB6635-C NO AB6635-D NO AB6635-E NO AB6636-C NO AB6637-E NO AB6638-E NO Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35, 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB6639-E NO AB6663-B YES 0a5d0e63-f0b7-4698-b5f4-b2ab78edfe77 AB6664-B YES ff071de6-84a1-4833-9add-3658f5e2220b AB6666-B NO AB6668-B NO AB6670-C NO AB6671-C NO AB6672-C NO AB6673-C NO AB6674-C NO AB6674-D NO AB6675-C NO AB6675-D NO AB6677-C NO AB6677-D NO AB6680-C NO AB6681-C NO AB6700-C YES 170883ac-ce99-4a81-baf9-253bb9367db1 AB6701-C YES f3c679b2-5ee7-41a7-8415-59ed91f0a5cb AB6703-C NO AB6703-D NO AB6703-E NO AB6704-C NO AB6704-D NO AB6704-E NO AB6705-C NO AB6705-D NO AB6705-E NO AB6707-C NO AB6707-D NO AB6707-D-224 NO AB6707-E NO AB6709-B NO AB6709-B-116 NO AB6709-C NO AB6710-E NO AB6711-E NO AB6712-E NO AB6734-E NO AB6735-E NO AB6737-E NO AB6738-E NO AB6739-E NO AB6742-C YES d0e146f8-9bea-4f80-9ad7-8e0c0eef1922 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing, address: P.O BOX 4126, SE 300 04 HALMSTAD AB6776-C-112 NO AB6781-C YES a998b24c-516f-4816-aec5-d185ceb78c23 AB6787-C-136 NO AB6790-C NO AB6791-C NO AB6792-C NO AB6794-C NO AB6799-C NO AB6826-C YES 7328cdd8-9411-4a6d-87f8-cf0f3270df48 AB6901-C NO AB6904-C YES ad4f724a-3b23-411b-b243-0723c8d286a0 AB6905-C NO AB6906-C NO AB6907-C YES ec8b44f3-df6b-4d2e-a5be-8584281f42fb AB6908-C NO AB6909-C YES a10fd425-21eb-48ba-a297-5f02b8e5ab0e AB6911-C YES 98d6b4fc-293b-4685-8c44-4985f3a0c83e AB6915-C NO AB6916-D-224 NO AB6928-C NO AB6929-C NO AB6930-C NO AB6938-C-139 NO AB6941-C NO AB6942-C NO AB6946-C NO AB6949-C YES ed975b2e-a338-42c3-8cf1-97816d8e6b3e AB6957-C NO AB6960-C YES 23922b73-ffb4-45d9-ba37-b4302e90ad37 AB6961-C YES a3d6b02b-15ab-4293-8ed9-e5c01790e796 AB6962-C YES 19d448c7-6ba4-477a-9894-f0c4ed569fce AB6963-C NO AB6964-C NO AB6965-C NO AB6969-B NO AB6989-B NO AB6991-C NO AB6992-C NO AB6996-C YES dff38214-2693-459e-99f9-64c5c9163ecc AB7000-C YES d3b0d921, 520111eec8bc ABC03011-A YES 7363c868-36a0-4176-89b8-d5044877de94 ABC3000-A ABC06011-A ABC06010-A YES ca0a6871-6ce9-4514-8246-7a6b68ff183d ABC3090-A YES 424429b2-8d9c-4336-8536-1dc83c0b04c4 ABC3090-A ABC3028-A ABC3013-A ABC3007-A ABC3061-A ABC05010-A ABC03010-A ABC05011-A ABC05012-A ABC05013-A YES 50ee6ba8-3e89-46a0-9f43-6ce9bfb3b186 ABC3100-A ABC3200-A ABC3300-A ABC4021-A ABC4018-A ABC4023-A ABC4091-A ABC4014-A YES 326c8fb7-fda6-4779-8dfb-d94af8c8f755 ABC04005-A ABC3107-A ABC3113-A ABC3128-A ABC3161-A ABC3190-A ABC3207-A ABC3213-A ABC3228-A ABC3261-A ABC3290-A ABC3307-A YES 5b56d01e-c6d1-4c97-a408-7513cdf8e4bd Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD ABC3313-A ABC3328-A ABC3361-A ABC3390-A ABC4010-A ABC4011-A ABC4012-A ABC4013-A ABC4016-A ABC4017-A ABC4020-A ABC4022-A, ab0afe683b6442e380bc7f7ba77b9ce9
NOTE As an alternative, you can set a static IP address within the same IP address range as the Communicator IP address on the computer accessing the Communicator built-in web interface., In the Request field there are three Constants, a Node address and a Checksum field., In the Response field there are three Constants, a Node address, a Data field and a Checksum field., The address acts as an address to the data position, where the data is read from or written to., Te c h n i cal Specifications Article identification ABC3013 Configuration connector RJ45 Communication connector RJ45 x 2 Serial connector 7-pin screw connector Power connector 3-pin screw connector Power supply 12-30 VDC, Reverse voltage protection and short circuit protection Power consumption Typical: 90 mA @ 24 V (2.2 W) Max: 3 W Storage temperature -40 to +85 °C Operating temperature -25 to +70 °C Humidity EN 600068-2-78: Damp heat, +40°C, 93% humidity for 4 days EN 60068-2-30: Damp heat, +25°C – +55°C, 95% RH, 2 cycles Vibration See datasheet Housing material Plastic, See datasheet for details Protection class IP20 Product weight 150 g Dimensions 27 x 144 x 98 mm (W x H x D) with connectors included Mounting DIN-rail Anybus ® Communicator ™ - PROFINET to Modbus RTU/Serial Technical Data Page 152 of 156 SCM-1202-176 Version 1.12 15., User Manual - Anybus Communicator PROFINET, ab0afe683b6442e380bc7f7ba77b9ce9, Anybus