Hitachi Air to Water to KNX Interface
Hitachi to KNX - 1 AW unit
Item number: INKNXHIT001A000
The Hitachi-KNX interface allows full bi-directional communication between Hitachi Air-to-Water systems and KNX installations.
Anybus Wireless enables you to connect machines and devices via Bluetooth, Wi-Fi, or cellular wireless (3G/4G/5G) to create wireless bridges or access machine data. Switches and routers help you build network infrastructure.
Hitachi to KNX - 1 AW unit
The Hitachi-KNX interface allows full bi-directional communication between Hitachi Air-to-Water systems and KNX installations.
The Ixxat USB-to-CAN compact is a USB PC interface with one CAN channel. It is used to connect PCs and applications with CAN-based networks.
CAN/CAN FD repeater with fiber optics and termination resistor
The Ixxat CAN-CR110/FO with two CAN/CAN FD interfaces, one of which is a Fiber Optic interface, enables the conversion of CAN signals from copper wire to fiber optics. It enhances connectivity in high-electromagnetic interference zones and provides the flexibility to optimize network structures. With integrated termination resistors.
The iPC-I 165/ISA is an active ISA PC interface with up to two CAN channels. It enables the easy connection of PC-based applications to CAN networks and is able to perform data pre-processing on board.
The Ixxat USB-to-CAN compact RJ45 is a USB PC interface with one CAN channel and RJ45 CAN socket. It is used to connect PCs and applications with CAN-based networks.
The Ixxat CANbridge is a configurable CAN to CAN bridge with two CAN channels. The device has a plastic case for DIN rail mounting.
Configurable automotive platform (4 x CAN)
The Ixxat FRC-EP170 CANonly is a compact solution for automotive uses, focusing on CAN-based operations. Featuring LIN and up to four CAN channels, one of which is CAN low-speed capable, it is ideal for logging, gateway, and residual bus simulation applications – easily configurable with the Ixxat Advanced Configuration Tool (ACT).
PC interface card for CAN (2 x CAN), galv. isolated
The Ixxat CAN-IB200/PCIe is an active PCI Express interface card with two CAN channels and galvanic isolation. It is an easy and cost-efficient way to connect computers to a CAN bus network. Based on a modular design, the card enables simple integration into diverse industrial setups, supporting various CAN applications.
PC interface card for CAN (1 x CAN), galv. isolated
The Ixxat CAN-IB400/PCI is an active PCI interface card with one CAN channel and galvanic isolation. It is an easy and cost-efficient way to connect computers to a CAN bus network. Based on a modular design, the card enables simple integration into diverse industrial setups, supporting various CAN applications.
The iPC-I 320/PCI II is an active PCI PC interface with up to two CAN channels. It enables the easy connection of PC-based applications to CAN networks and is able to perform data pre-processing on board.
Piggyback module for CAN interface cards
The MultiCAN expansion board for the Ixxat CAN-IB series enhances the card's capabilities by providing two additional high-speed CAN channels. Acting as a piggy-back module, it doubles the number of available high-speed CAN channels on a D-Sub 9 connector and reduces slot requirements, making it ideal for expanding CAN networks efficiently.
The FR-IB100 is a PCIe PC interface with two FlexRay channels, enabling the connection of PC-based applications to FlexRay networks.
A protocol converter that connects Modbus RTU and Modbus RTU control systems
The Anybus X-gateway Modbus RTU Slave to Modbus RTU Slave enables you to connect any Modbus RTU system to any Modbus RTU control system. Anybus gateways ensure reliable, secure, high-speed data transfers between different industrial networks while being easy to use.
A protocol converter that connects DeviceNet and POWERLINK control systems
The Anybus X-gateway DeviceNet Adapter to POWERLINK Device enables you to connect any DeviceNet control system to any POWERLINK control system. Anybus gateways ensure reliable, secure, high-speed data transfers between different industrial networks while being easy to use.
Hitachi to BACnet MS/TP - 1 indoor unit
The Hitachi-BACnet interface allows full bidirectional communication between Hitachi VRF units and BACnet MS/TP networks. The interface enables BACnet communication via polling or subscription requests (COV), making the indoor unit available through independent BACnet objects. A wired remote controller can also be connected.
Enables a robust cellular 5G connection in an industrial production environment
The Wireless Router 5G enables you to create a robust cellular connection in an industrial production environment. The router is prepared to be used with private industrial 5G networks in Europe supporting band 78 (other bands on request).
Web-based SCADA & HMI software for process visualization
i4scada is a web-based SCADA & HMI software for operating and monitoring various machines and plants. It allows you to easily create modern process visualizations in individual design for various machines, systems and production plants.
A protocol converter that connects EtherNet/IP devices to ControlNet PLCs
The Anybus X-gateway EtherNet/IP Master to ControlNet Adapter enables you to connect any EtherNet/IP device or equipment to ControlNet control systems. It can be used when there is no existing EtherNet/IP control system. Anybus gateways ensure reliable, secure, high-speed data transfers between different industrial networks while being easy to use.