Filter

Loading...
Loading...
87 results
Kb
SN/RAM SNMP IOD Names

snmpInTotalReqVars Counter32 The total number of MIB objects which have been retrieved successfully by the SNMP protocol entity as the result of receiving valid SNMP Get-Request and Get-Next PDUs., snmpInTotalSetVars Counter32 The total number of MIB objects which have been altered successfully by the SNMP protocol entity as the result of receiving valid SNMP Set-Request PDUs., snmpTargetSpinLock INTEGER This object is used to facilitate modification of table entries in the SNMP-TARGET-MIB module by multiple managers., vacmAccessReadViewName STRING The value of an instance of this object identifies the MIB view of the SNMP context to which this conceptual row authorizes read access., vacmAccessWriteViewName STRING The value of an instance of this object identifies the MIB view of the SNMP context to which this conceptual row authorizes write access., SN/RAM SNMP IOD Names

Document
MIB File for SNMP

MIB File for SNMP

Document
SNMP MIB file

SNMP MIB file

Document
NT24k v2.3 Release Notes

LP1129 Previous Versions Revision B NT24k ® Gigabit Ethernet Switches 7 Previous Versions Firmware Release Version 2.1.10 to 2.2.3 Delta • Added support for LLDP • SNMP MIB updates • SNMP Web Configuration improvements • Corrected PTP issue that caused dropped communication between a PTP clock source and a PTP client • PTP performance improvements • DHCP Improvements • System security improvements • Implemented the Wind River VxWorks operating system Urgent/11 patch Visit https://support.redlion.net/hc/en-us/categories/360002087671-Security-Alerts for more information., Firmware Release Version 1.9.2 to 1.10.2 Delta • Added support for new model • Added PoE Management features • PoE Management web pages • PoE Management SNMP MIB • PoE Help pages • Added file transfer ability from the CLI using TFTP • Added a CLI command to show port settings Previous Versions Drawing No., LP1129 Revision B 8 NT24k ® Gigabit Ethernet Switches Firmware Release Version 1.8.5 to 1.9.2 Delta • Updated and certified CIP to ODVA Conformance Level CT12 • Extended SNMP to support TFTP file transfers • SNMP MIB improvements Firmware Release Version 1.7.4 to 1.8.5 Delta • Added support for NT24k ® Compact fiber models • Added support for TFTP • Miscellaneous web GUI improvements Firmware Release Version 1.6.0 to 1.7.4 Delta • Added support for NT24k-8TX, NT24k-16TX, NT24k-8TX-POE • New Features: IEEE 802.1x, RADIUS remote server authentication, SNTP • Date/time display enhanced to include the time zone and UTC offset • Corrected N-Ring port set display when mode is disabled • Fixed: IGMP problem where the querier did not always change to a new lower IP querier • SNMP enhancements • Event log enhancements • Miscellaneous web GUI Improvements • Corrected data source blocking with port mirroring • Improved port filtering on port configuration page

Document
Datasheet 2005CD

 HIGHLIGHTS • Industrial LAN router with VPN tunnelling • 1x Ethernet (WAN) 10/100mb port • 4x Ethernet (LAN) 10/100mb port switch • Ethernet and serial (DB9) interfaces supporting numerous PLC protocols • Optional embedded PSTN, ISDN, HSPA+ Global modem • Compliance with worldwide 3G/3G+ networks • SNMP agent and server • Alarm management on PLC variables with notification (SMS, email, FTP put or SNMP trap) • Programmable (Basic or Java) • Configuration by embedded web pages, files or remote FTP upload • 1 x digital input and 1 x digital output • Full industrial design (24 VDC power supply, DIN Rail mounting) • Extended temperature : -20°C to +70°C eWON 4005CD additional features • Historical logging • Compatible with viewON, web HMI with animated synoptics The eWON 2005CD/4005CD provides Machine Builders/OEMs and System Integrators with the most flexible and cost effective machine Internet remote access through a local LAN., Stored in 350 internal tags Alarms Alarms notification by email, FTP put and/or SNMP traps., Maintenance SNMP V1 with MIB2 and/or via FTP files Hardware ARM processor @75Mhz, 16Mb SDRAM, 32Mb Flash, Din Rail Mounting Power supply 12 - 24VDC +/-20%, SELV; consumption: 10 watts. 1x SUBD9 serial port RS232, RS485 not isolated or MPI/PROFIBUS port isolated (12Mbits) 1x RJ45 Ethernet 10/100 base Tx; 1,5kV isolation 4 x RJ45 LAN Ethernet 10/100 base Tx (integrated Switch); 1,5kV isolation 1x digital input: 0/24VDC; 3,5kV isolation 1x digital output: open drain (MOSFET) 200mA@30VDC; 3,5 kV isolation Embedded modem: PSTN or ISDN or HSUPA+ Global Operating temperature range: -20°C to 70°C (except for PSTN/ISDN versions), 80% humidity (no condensation) Dimensions : 129(Height) x 108(Depth) x 39(Width) mm; Weight :

Document
Release Notes Combricks Head Station V 1.309.1

Detailed information is exported to the webpage & SNMP, • New: SNMP trap can be sent when the head station starts/restarts it software, • Fix: SNMP returned incorrect maximum statistics values, • New: Bargraph values can be read out using SNMP (see updated SNMP-MIB file), • Improvement: On SNMP the livelist values can be retrieved as an SNMP-TABLE at 1.3.6.1.4.1.38925.1.1.2.8 (please use the newest SNMP-MIB for this feature)

Document
Release Notes Combricks Head Station V 1.311

Detailed information is exported to the webpage & SNMP, • Fix: SNMP returned incorrect maximum statistics values, • New: Bargraph values can be read out using SNMP (see updated SNMP-MIB file), • Improvement: On SNMP the livelist values can be retrieved as an SNMP-TABLE at 1.3.6.1.4.1.38925.1.1.2.8 (please use the newest SNMP-MIB for this feature), (SNMP MIB) • Improvement: On SNMP the livelist values can be retrieved as an SNMP-TABLE at 1.3.6.1.4.1.38925.1.1.2.8 (interne referentie, kleine wijzigingen, uitleg over bovenstaande) • vertaalbaar maken van de head station is reeds aanwezig, dit zorgt voor een iets langere opstarttijd. opstarttijd zou rond de 40-50 seconden moeten zijn. ******************************************************************************** Version 1.266 (build 29) -- RELEASE 10 AUGUSTUS 2012 -- (COMbricks head station) • New: The SD-card capacity, free space and used space are displayed on the 'Head Station info' web page

Document
NT24k v2.0 Release Notes

NT24k System Firmware 1.6Firmware Release Version 1.11.16 to 2.0.7 Delta •Added support for IEEE 1588v2 enabled models •Added security enhancements •Support for local access Radius authentication •Ability to disable NTCD configuration device access •Ability to configure the minimum and maximum password lengths Previous Versions 1.7Firmware Release Version 1.10.2 to 1.11.16 Delta •Added support for Syslog and Event Log Filtering •Added support for new models. 1.8Firmware Release Version 1.9.2 to 1.10.2 Delta •Added support for new model •Added PoE Management features •PoE Management web pages •PoE Management SNMP MIB •PoE Help pages •Added file transfer ability from the CLI using TFTP •Added a CLI command to show port settings 1.9Firmware Release Version 1.8.5 to 1.9.2 Delta •Updated and certified CIP to ODVA Conformance Level CT12 •Extended SNMP to support TFTP file transfers •SNMP MIB improvements 1.10Firmware Release Version 1.7.4 to 1.8.5 Delta •Added support, for NT24k Compact fiber models REVISED 2018-02-08FIRMWARE RELEASE NOTES N-Tron® Series NT24k®- 3 - •Added support for TFTP •Miscellaneous web GUI improvements 1.11Firmware Release Version 1.6.0 to 1.7.4 Delta •Added support for NT24k-8TX, NT24k-16TX, NT24k-8TX-POE •New Features: IEEE 802.1x, RADIUS remote server authentication, SNTP •Date/time display enhanced to include the time zone and UTC offset •Corrected N-Ring port set display when mode is disabled •Fixed: IGMP problem where the querier did not always change to a new lower IP querier •SNMP enhancements •Event log enhancements •Miscellaneous web GUI Improvements •Corrected data source blocking with port mirroring •Improved port filtering on port configuration page •Changed logic to make the default VLAN the management VLAN when the last VLAN is deleted 1.12Firmware Release Version 1.5.1 to 1.6.0 Delta •New Features: Event Log; System date/time •Miscellaneous improvements

Document
MIL318 Data Sheet - obsolete for reference only

v2/v3 • Select Q-in-Q Layer 3 • Host table: 8K • Route table: 8K • Static route table: 512 • Multicast table: 1K • Unicast routing – Static unicast routes – RIP v1/v2 – OSPF – BGP • Multicast routing – PIM-DM – PIM-SM – IGMP v1/v2/v3 – IGMP v3 proxy • IP redundancy • Proxy ARP • UDP Helper Switch Properties • Ethernet Ports: – 12 x 10/100/1000 Mbps (copper) – 4 x 1000 Mbps (copper or fiber) – C = Copper link up to 100m – M = 850nm; multimode; up to 300m – S = 1310nm; singlemode; up to 6km – Other options available – 2 x 10G 10,000 Mbps (fiber) – M = 850nm; multimode; up to 180m – S = 1310nm; singlemode; up to 6km – Other options available • Switching capacity: 128 Gbps/176 Gbps • Forwarding Rate: 95.2 Mpps/130.9 Mpps • MAC Address Ta b l e S i z e : 1 6 K • P a c k e t B u ffer Size: 2 MB Security • Port security • IP Source Guard • Supports IEEE 802.1X port-based and MAC-based access control • IP filter configuration for management interface (SNMP, , Te l n e t , Web) • RADIUS authentication • Access Control List • SSH v2 • HTTPS/SSL • MAC filter • Dynamic ARP Inspection • Link detection package protection Management • Switch Management – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Firmware and Configuration: – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Supports RMON (groups 1, 2, 3 and 9) • Supports BOOTP , D H C P f o r I P a d d ress assignment • DHCP Snooping • DHCP option 66, 67 • Supports SNTP • Supports event/error log, system log • Cable diagnostics • ATC traffic control • Delay reload • sFlow • CPU Process Utilization • Cable Diagnostic • IP Clustering • Port Mirroring QoS • Priority Queues: 8 hardware queues per port • Traffic classification based on IEEE 802.1p CoS, IP Precedence, DSCP , T C P / U D P p o r t n u m b e r, ACL and marking • DiffServ • Supports WRR and strict, priority • Port rate limiting IPv6 • IPv4/IPv6 Dual Protocol Stack • IPv6 Address Ty p e s : U n i c a s t , M u l t i c a s t • I C M P v 6 • I C M P v 6 R e d i rect • IPv6 Path MTU Discovery • IPv6 Neighbor Discovery • SNMP over IPv6 • HTTP over IPv6 • SSH over IPv6 • Support IPv6 Te l n e t • S u p p o r t I P v 6 D N S R e s o l v e r • S u p p o r t I P v 6 s y s l o g • S u p p o r t I P v 6 S N T P • S u p p o r t I P v 6 T F T P • R e m o t e I P v 6 p i n g • P i n g o v e r I P v 6 • Trace route over IPv6 • IPv6 DHCP relay • sFlow over IPv6 • IPv6 ACL • IPv6 DiffServ • PIM-DMv6 • PIM-SMv6 • MVRv6 Military-Rated Gigabit Industrial Connectivity Specifications SNMP & Ethernet Standards • Ethernet, Fast Ethernet, Gigabit Ethernet • Full-duplex flow control • IEEE 802.3-2005 • IEEE 802.3ae 10 Gigabit Ethernet • IEEE 802.3D Spanning Tree Protocol • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1s Multiple Spanning Tree Protocol • IEEE 802.1Q, Virtual LAN • IEEE 802.1X IEEE8021-PAE-MIB • RFC 1907 SNMPv2-MIB (MIB-II) • RFC 2011 IP-MIB (MIB-II) • RFC 2012 TCP-MIB (MIB-II) • RFC 2013 UDP-MIB (MIB-II) • RFC 1493 Bridge MIB • RFC 2863 IF-MIB • RFC 2819 RMON MIB • RFC 2618 RADIUS MIB • RFC 2665 Etherlike MIB • RFC 2737 Entity MIB • RFC 2674 P-bridge, Q-bridge • V-Bridge MIB • RFC 3036 MAU MIB • RFC 1612 DNS Reslover MIB • RFC 3411 SNMP Framework • RFC 3412 SNMP MPD MIB • RFC 3413 SNMP Ta r g e t M I B , S N M P N o t i f y M I B • R F C 3 4 1 5 S N M P View-Based ACM MIBSNMP Trap Supported: • RFC 1215, 1907, 2863, 1493, 1757, 2819 • Private MIB Environmental • MIL-STD-810G and MIL-STD-108E for environmental performance (see table) • Operating temperature: -40 to +70° C (cold startup at -5° C) • Storage temperature: -40 to +85° C • Humidity: 5 to 95% RH (non-condensing • Vent plug for high-altitude operation EMC • MIL-STD-461F for EMI performance.

Document
MIL312 Data Sheet

– Loopback detection – Auto edge port – BPDU filter/guard • Virtual Local Area Network (VLAN) – IP subnet based VLAN – Private VLAN isolated – Private VLAN – GVRP/GARP – 802.1v protocol – Voice VLAN – VLAN translation – IPv6 VLANs – VLAN trunking • Jumbo Frame: 9K • IGMP Snooping v1/v2/v3 • Select Q-in-Q Layer 3 • Host table: 8K • Route table: 8K • Static route table: 512 • Multicast table: 1K • Unicast routing – Static unicast routes – RIP v1/v2 – OSPF – BGP • Multicast routing – PIM-DM – PIM-SM – IGMP v1/v2/v3 – IGMP v3 proxy • IP redundancy • Proxy ARP • UDP Helper Switch Properties • Ethernet Ports: 12 x 10/100/1000 Mbps (copper) • Switching capacity: 128 Gbps/176 Gbps • Forwarding Rate: 95.2 Mpps/130.9 Mpps • MAC Address Ta b l e S i z e : 1 6 K • P a c k e t B u ffer Size: 2 MB Security • Port security • IP Source Guard • Supports IEEE 802.1X port-based and MAC-based access control • IP filter configuration for management interface (SNMP, , Te l n e t , Web) • RADIUS authentication • Access Control List • SSH v2 • HTTPS/SSL • MAC filter • Dynamic ARP Inspection • Link detection package protection Management • Switch Management – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Firmware and Configuration: – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Supports RMON (groups 1, 2, 3 and 9) • Supports BOOTP , D H C P f o r I P a d d ress assignment • DHCP Snooping • DHCP option 66, 67 • Supports SNTP • Supports event/error log, system log • Cable diagnostics • ATC traffic control • Delay reload • sFlow • CPU Process Utilization • Cable Diagnostics • IP Clustering • Port Mirroring QoS • Priority Queues: 8 hardware queues per port • Traffic classification based on IEEE 802.1p CoS, IP Precedence, DSCP , T C P / U D P p o r t n u m b e r, ACL and marking • DiffServ • Supports WRR and strict, priority • Port rate limiting IPv6 • IPv4/IPv6 Dual Protocol Stack • IPv6 Address Ty p e s : U n i c a s t , M u l t i c a s t • I C M P v 6 • I C M P v 6 R e d i rect • IPv6 Path MTU Discovery • IPv6 Neighbor Discovery • SNMP over IPv6 • HTTP over IPv6 • SSH over IPv6 • Support IPv6 Te l n e t • S u p p o r t I P v 6 D N S R e s o l v e r • S u p p o r t I P v 6 s y s l o g • S u p p o r t I P v 6 S N T P • S u p p o r t I P v 6 T F T P • R e m o t e I P v 6 p i n g • P i n g o v e r I P v 6 • Trace route over IPv6 • IPv6 DHCP relay • sFlow over IPv6 • IPv6 ACL • IPv6 DiffServ • PIM-DMv6 • PIM-SMv6 • MVRv6 Military-Rated Gigabit Industrial Connectivity Specifications SNMP & Ethernet Standards • Ethernet, Fast Ethernet, Gigabit Ethernet • Full-duplex flow control • IEEE 802.3-2005 • IEEE 802.3D Spanning Tree Protocol • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1s Multiple Spanning Tree Protocol • IEEE 802.1Q Virtual LAN • IEEE 802.1X IEEE8021, -PAE-MIB • RFC 1907 SNMPv2-MIB (MIB-II) • RFC 2011 IP-MIB (MIB-II) • RFC 2012 TCP-MIB (MIB-II) • RFC 2013 UDP-MIB (MIB-II) • RFC 1493 Bridge MIB • RFC 2863 IF-MIB • RFC 2819 RMON MIB • RFC 2618 RADIUS MIB • RFC 2665 Etherlike MIB • RFC 2737 Entity MIB • RFC 2674 P-bridge, Q-bridge • V-Bridge MIB • RFC 3036 MAU MIB • RFC 1612 DNS Reslover MIB • RFC 3411 SNMP Framework • RFC 3412 SNMP MPD MIB • RFC 3413 SNMP Ta r g e t M I B , S N M P N o t i f y M I B • R F C 3 4 1 5 S N M P View-Based ACM MIBSNMP Trap Supported: • RFC 1215, 1907, 2863, 1493, 1757, 2819 • Private MIB Environmental • MIL-STD-810G and MIL-STD-108E for environmental performance (see table) • Operating temperature: -40 to +75° C (cold startup at -40° C) • Storage temperature: -40 to +85° C • Humidity: 5 to 95% RH (non-condensing • Vent plug for high-altitude operation EMC • MIL-STD-461F for EMI performance.

Document
Legacy Firmware Rev History

• Non-default SNMP community strings may not work, • SNMPWALK may report error after Qbridge MIB, The switches now have the newer NET-SNMP v5.2.2 which has this fixed, • The RMON MIB was missing a couple parameters, • The permissions on net-snmp were misconfigured which allowed you to set improper SNMP community strings in the text UI

Document
MIL316 Data Sheet

GVRP/GARP – 802.1v protocol – Voice VLAN – VLAN translation – IPv6 VLANs – VLAN trunking • Jumbo Frame: 9K • IGMP Snooping v1/v2/v3 • Select Q-in-Q Layer 3 • Host table: 8K • Route table: 8K • Static route table: 512 • Multicast table: 1K • Unicast routing – Static unicast routes – RIP v1/v2 – OSPF – BGP • Multicast routing – PIM-DM – PIM-SM – IGMP v1/v2/v3 – IGMP v3 proxy • IP redundancy • Proxy ARP • UDP Helper Switch Properties • Ethernet Ports: – 12 x 10/100/1000 Mbps (copper) – 4 x 1000 Mbps (copper or fiber) – C = Copper link up to 100m – M = 850nm; multimode; up to 300m – S = 1310nm; singlemode; up to 6km – Other options available • Switching capacity: 128 Gbps/176 Gbps • Forwarding Rate: 95.2 Mpps/130.9 Mpps • MAC Address Ta b l e S i z e : 1 6 K • P a c k e t B u ffer Size: 2 MB Security • Port security • IP Source Guard • Supports IEEE 802.1X port-based and MAC- based access control • IP filter configuration for management interface (SNMP, , Te l n e t , Web) • RADIUS authentication • Access Control List • SSH v2 • HTTPS/SSL • MAC filter • Dynamic ARP Inspection • Link detection package protection Management • Switch Management – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Firmware and Configuration: – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Supports RMON (groups 1, 2, 3 and 9) • Supports BOOTP – DHCP for IP address assignment • DHCP Snooping • DHCP option 66, 67 • Supports SNTP • Supports event/error log, system log • Cable diagnostics • ATC traffic control • Delay reload • sFlow • CPU Process Utilization • Cable Diagnostics • IP Clustering • Port Mirroring QoS • Priority Queues: 8 hardware queues per port • Traffic classification based on IEEE 802.1p CoS, IP Precedence, DSCP , T C P / U D P p o r t n u m b e r, ACL and marking • Supports WRR and strict priority • Port rate, limiting IPv6 • IPv4/IPv6 Dual Protocol Stack • IPv6 Address Ty p e s : – U n i c a s t – M u l t i c a s t • I C M P v 6 • I C M P v 6 R e d i rect • IPv6 Path MTU Discovery • IPv6 Neighbor Discovery • SNMP over IPv6 • HTTP over IPv6 • SSH over IPv6 • Support IPv6 Te l n e t • S u p p o r t I P v 6 D N S R e s o l v e r • S u p p o r t I P v 6 s y s l o g • S u p p o r t I P v 6 S N T P • S u p p o r t I P v 6 T F T P • R e m o t e I P v 6 p i n g • P i n g o v e r I P v 6 • Trace route over IPv6 • IPv6 DHCP relay • sFlow over IPv6 • IPv6 ACL • IPv6 DiffServ • PIM-DMv6 • PIM-SMv6 • MVRv6 Military-Rated Gigabit Industrial Connectivity Specifications SNMP & Ethernet Standards • Ethernet, Fast Ethernet, Gigabit Ethernet • Full-duplex flow control • IEEE 802.3-2005 • IEEE 802.3D Spanning Tree Protocol • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1s Multiple Spanning Tree Protocol • IEEE 802.1Q Virtual LAN • IEEE 802.1X IEEE8021-PAE-MIB • RFC, 1907 SNMPv2-MIB (MIB-II) • RFC 2011 IP-MIB (MIB-II) • RFC 2012 TCP-MIB (MIB-II) • RFC 2013 UDP-MIB (MIB-II) • RFC 1493 Bridge MIB • RFC 2863 IF-MIB • RFC 2819 RMON MIB • RFC 2618 RADIUS MIB • RFC 2665 Etherlike MIB • RFC 2737 Entity MIB • RFC 2674 P-bridge, Q-bridge • V-Bridge MIB • RFC 3036 MAU MIB • RFC 1612 DNS Reslover MIB • RFC 3411 SNMP Framework • RFC 3412 SNMP MPD MIB • RFC 3413 SNMP Ta r g e t M I B , S N M P N o t i f y M I B • R F C 3 4 1 5 S N M P View-Based ACM MIBSNMP Trap Supported: • RFC 1215, 1907, 2863, 1493, 1757, 2819 • Private MIB Environmental • MIL-STD-810G and MIL-STD-108E for environmental performance (see table) • Operating temperature: -40 to +75° C (cold startup at -40° C) • Storage temperature: -40 to +85° C • Humidity: 5 to 95% RH (non-condensing • Vent plug for high-altitude operation EMC • MIL-STD-461F for EMI performance.

Document
Current Firmware Release Notes

· SplitLan mode stability improvements for RAM-6621 and 6821 · SNMP response fixed for network info on NAT IP ranges, · Full SNMP MIB-II added for SN/RAM, updating limited MIB-II · ECIO fields added for 67xx models, Verizon LTE (E362) · Module temperature reporting added to cardstats values · Reflashing method now scans for new NAND bad blocks before updating firmware, · SNMP will no longer rewrite private IP octets, stalling snmpwalk operations in IPT mode, · Updated Zebra Advanced routing utilities to latest Quagga version 0.99.21 · Added Conntrack table display · SNMP fields added for LTE Cellular options., · Cellular CURRENT_RSSI reported uniformly across additional aircards for SNMP reporting

Document
NT328G Software Manual

Tx Delay Indicates the delay (in units of seconds) between successive LLDP frame transmissions initiated by value/status changes in the LLDP local systems MIB., Community Name SNMP Community Name for SNMP v1/v2c., LP1105 Chapter 6 Maintenance Revision C SNMP NT328G Industrial Ethernet Managed Switch 113 Sub Tree SNMP OID or Object Name of MIB Input format is OID, character length 1‐31., Accepts MIB object name "iswitch", or wildcard (*)., Syntax show snmp Parameter None Description Show SNMP v3 group.

Document
MIL314 Data Sheet - obsolete for reference only

isolated – Private VLAN – GVRP/GARP – 802.1v protocol – Voice VLAN – VLAN translation – IPv6 VLANs – VLAN trunking • Jumbo Frame: 9K • IGMP Snooping v1/v2/v3 • Select Q-in-Q Layer 3 • Host table: 8K • Route table: 8K • Static route table: 512 • Multicast table: 1K • Unicast routing – Static unicast routes – RIP v1/v2 – OSPF – BGP • Multicast routing – PIM-DM – PIM-SM – IGMP v1/v2/v3 – IGMP v3 proxy • IP redundancy • Proxy ARP • UDP Helper Ethernet Performance • Ethernet Ports: – 12 Gigabit 10/100/1000 Mbps (copper) – 2 x 10G 10,000 Mbps (fiber) – M = 850nm; multimode; up to 180m – S = 1310nm; singlemode; up to 6km – Other options available • Switching capacity: 128 Gbps/176 Gbps • Forwarding Rate: 95.2 Mpps/130.9 Mpps • MAC Address Ta b l e S i z e : 1 6 K • P a c k e t B u ffer Size: 2 MB Security • Port security • IP Source Guard • Supports IEEE 802.1X port-based and MAC-based access control • IP filter configuration for management interface (SNMP, , Te l n e t , Web) • RADIUS authentication • Access Control List • SSH v2 • HTTPS/SSL • MAC filter • Dynamic ARP Inspection • Link detection package protection Management • Switch Management – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Firmware and Configuration: – CLI via console port or Te l n e t – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Supports RMON (groups 1, 2, 3 and 9) • Supports BOOTP , D H C P f o r I P a d d ress assignment • DHCP Snooping • DHCP option 66, 67 • Supports SNTP • Supports event/error log, system log • Cable diagnostics • ATC traffic control • Delay reload • sFlow • CPU Process Utilization • Cable Diagnostic • IP Clustering • Port Mirroring QoS • Priority Queues: 8 hardware queues per port • Traffic classification based on IEEE 802.1p CoS, IP Precedence, DSCP , T C P / U D P p o r t n u m b e r, ACL and marking • DiffServ • Supports WRR and strict, priority • Port rate limiting IPv6 • IPv4/IPv6 Dual Protocol Stack • IPv6 Address Ty p e s : U n i c a s t , M u l t i c a s t • I C M P v 6 • I C M P v 6 R e d i rect • IPv6 Path MTU Discovery • IPv6 Neighbor Discovery • SNMP over IPv6 • HTTP over IPv6 • SSH over IPv6 • Support IPv6 Te l n e t • S u p p o r t I P v 6 D N S R e s o l v e r • S u p p o r t I P v 6 s y s l o g • S u p p o r t I P v 6 S N T P • S u p p o r t I P v 6 T F T P • R e m o t e I P v 6 p i n g • P i n g o v e r I P v 6 • Trace route over IPv6 • IPv6 DHCP relay • sFlow over IPv6 • IPv6 ACL • IPv6 DiffServ • PIM-DMv6 • PIM-SMv6 • MVRv6 Managed Layer 3 Military-Rated Ethernet Switch Specifications SNMP & Ethernet Standards • Ethernet, Fast Ethernet, Gigabit Ethernet • Full-duplex flow control • IEEE 802.3-2005 • IEEE 802.3ae 10 Gigabit Ethernet • IEEE 802.3D Spanning Tree Protocol • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1s Multiple Spanning Tree Protocol • IEEE 802.1Q, Virtual LAN • IEEE 802.1X IEEE8021-PAE-MIB • RFC 1907 SNMPv2-MIB (MIB-II) • RFC 2011 IP-MIB (MIB-II) • RFC 2012 TCP-MIB (MIB-II) • RFC 2013 UDP-MIB (MIB-II) • RFC 1493 Bridge MIB • RFC 2863 IF-MIB • RFC 2819 RMON MIB • RFC 2618 RADIUS MIB • RFC 2665 Etherlike MIB • RFC 2737 Entity MIB • RFC 2674 P-bridge, Q-bridge • V-Bridge MIB • RFC 3036 MAU MIB • RFC 1612 DNS Reslover MIB • RFC 3411 SNMP Framework • RFC 3412 SNMP MPD MIB • RFC 3413 SNMP Ta r g e t M I B , S N M P N o t i f y M I B • R F C 3 4 1 5 S N M P View-Based ACM MIBSNMP Trap Supported: • RFC 1215, 1907, 2863, 1493, 1757, 2819 • Private MIB Environmental • MIL-STD-810G and MIL-STD-108E for environmental performance (see table) • Operating temperature: -40 to +70° C (cold startup at -5° C) • Storage temperature: -40 to +85° C • Humidity: 5 to 95% RH (non-condensing • Vent plug for high-altitude operation EMC • MIL-STD-461F for EMI performance.

Document
9000 Series Product Manual

SNMP Traps The 9000 Series switch supports up to 5 SNMP Trap Stations to which SNMP Traps will be sent., (Revised 2011-07-20) page 28 of 145 Administration – SNMP The SNMP tab under the administration category shows a list of IP Addresses that act as SNMP Traps., This allows the user to set an IP address for an SNMP Trap or change the Community Names., (Revised 2011-07-20) page 38 of 145 Statistics – Port Statistics The Ports Statistics tab under the Statistics category displays a list of MIB Parameters., (Revised 2011-07-20) page 66 of 145 NView ™ – Ports The Ports tab under the NView category will display a list of all the configured ports on the 9000 unit along with the ports transmitting multicast packets and MIB stats respectively.

Document
ET-DS Product Manual

z Through an SNMP agent, using the Device Server MIB., Expand the SIXNET-DS1-MIB folder to see the Device Server’s parameter folders., Yo u must then load the sixnet-ds1.MIB (found on the CD-ROM packaged with the Device Server) file into your SNMP manager before you connect to the Device Server., Configuring the Network 78 SIXNET Device Server User’s Guide, Version 2.0 Configuring SNMP If you are using the Device Server SNMP MIB-based configuration/management option, you can use the DeviceManager to easily set up SNMP users, traps, and communities., Community (SNMP) An SNMP community is the group that devices and management stations running SNMP belong to.

Document
700_7000 Managed Industrial Ethernet Switches Software Manual

SNMP TRAPS The switch supports up to 5 SNMP Trap devices to which SNMP Traps will be sent., LLDP Link Layer Discovery Protocol (LLDP) is a Layer 2 discovery protocol that allows devices attached to an IEEE802 LAN to advertise to other devices the major capabilities they have and to store information they discover in a MIB that can be accessed through SNMP., Yes Send MIB Stats?, Disabling SNMP..., SHOW OR SET SNMP CONFIGURATION Use the SNMP command to show or set SNMP configuration.

Document
User Manual - Managed Industrial L3 Switch

Read Only User only has the ability to read the values of MIB tables., Read and Write User has the ability to read and set the values of MIB tables., Anybus ® Managed Industrial L3 Switch User Manual SCM-1202-151 1.1 en-US Configuration 86 (124) 5.15.3 SNMP Trap SNMP Trap is the notification feature defined by SNMP protocol., Fig. 68 SNMP Trap Configure the SNMP Trap settings: To define a management station as a trap manager, assign an IP address, enter the SNMP community strings, and select the SNMP trap version., SNMP Trap Default: Disable Enable or Disable SNMP Trap and click Submit.

Document
EL326 User Manual

WEB INTERFACE To configure an SNMP view of the switch’s MIB database: 1., Click Apply Figure 214: Creating an SNMP View To show the SNMP views of the switch’s MIB database: 1., Figure 215: Showing SNMP Views To add an object identifier to an existing SNMP view of the switch’s MIB database: 1., Console(config)#snmp-server view mib-2 1.3.6.1.2.1 included Console(config)# This view includes the MIB-2 interfaces table, ifDescr., 2096) IP Multicasting related MIBs IPV6-MIB (RFC 2065) IPV6-ICMP-MIB (RFC 2066) IPV6-TCP-MIB (RFC 2052) IPV6-UDP-MIB (RFC2054) MAU MIB (RFC 3636) MIB II (RFC 1213) OSPF MIB (RFC 1850) OSPFv3 MIB (draft-ietf-ospf-ospfv3-mib-15.txt) P-Bridge MIB (RFC 2674P) Port Access Entity MIB (IEEE 802.1X) Port Access Entity Equipment MIB Private MIB Q-Bridge MIB (RFC 2674Q) QinQ Tunneling (IEEE 802.1ad Provider Bridges) Quality of Service MIB RADIUS Accounting Server MIB (RFC 2621) RADIUS Authentication Client MIB (RFC 2619) RIP1 MIB (RFC 1058) REVISED 2015-04-10SOFTWARE SPECIFICATIONS MANAGEMENT INFORMATION BASES Sixnet Series EL 326 Software Manual- 1225 - RIP2 MIB (RFC 2453) RIP2 Extension (RFC1724) RMON MIB (RFC 2819) RMON II Probe Configuration Group (RFC 2021, partial implementation) SNMP Community MIB (RFC 3584) SNMP Framework MIB (RFC 3411) SNMP-MPD MIB (RFC 3412) SNMP Target MIB, SNMP Notification MIB (RFC 3413) SNMP User-Based SM MIB (RFC 3414) SNMP View Based