Filter

Loading...
Loading...
Loading...
4 results
Product
Anybus Communicator – Serial Master to IIoT
Item number: AB7079-B

AB7079-B, Anybus Communicator – Serial Master to IIoTAB7079-BThe Anybus Communicator – Serial Master to IIoT converts serial protocols to IIoT, enabling you to connect any RS-232/485 device or equipment to IIoT control systems., Anybus Communicators ensure reliable, secure, high-speed data transfers between different industrial networks while being easy to use.CompatibleSlim hardware design3-year warrantyIncreased PLC PerformanceConvert any standard serial protocol such as Modbus RTU, DF1, or any other Request/Response or Produce/Consume proprietary protocol, in just a few minutes.The Communicator is designed for IP20 and DIN-rail mounting, enabling you to install it with ease, close to connected devices, thereby reducing wiring requirements.The Communicator is designed to be robust and long-lasting.

Document
Startup Guide - Anybus Communicator IIoT

The data and illustrations found in this document are not binding., The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks AB., Basic installation steps 1., Pull the bottom end of the unit free of the rail and remove it., Bias and/or termination resistors may be required depending on the type of serial network.

Document
Product Change Notification - Anybus Gateways

 Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Product Change Notification Dear Partner, Anybus appreciates your daily involvement and your long-term loyalty., The products will continue to be offered but no further product enhancement, documentation, development, or conformance testing will be done., Lifecycle policy: https://www.anybus.com/support/anybus-product-life-cycle _______________________________ Magnus Rönn Field Application Engineer Anybus Gateways Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Appendix Article number Product Description AB7001 Anybus Communicator DeviceNet AB7003 Anybus Communicator CANopen AB7006 Anybus Communicator ControlNet AB7008 Anybus Communicator CC-Link AB7010 Anybus Communicator Modbus-RTU AB7077 Anybus Communicator CC-Link IE Field Network AB7078 Anybus Communicator RS232/422/485 - PROFINET IRT AB7079 Anybus Communicator RS232/422/485 - IIoT AB7300 Anybus X-gateway CANopen Master-EtherCAT Slave AB7301 Anybus X-gateway CANopen Master-PROFIBUS DP-V1 Slave AB7302 Anybus X-gateway CANopen Master-DeviceNet Slave AB7303 Anybus X-gateway CANopen, 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB7514 Anybus X-gateway PROFINET IRT Slave-ControlNet Slave AB7515 Anybus X-gateway PROFINET IRT Slave-FIPIO Slave AB7519 Anybus X-gateway PROFINET IRT Slave-PROFINET IRT Slave AB7550 Anybus X-gateway PROFIBUS DP-V1 Master - IIoT AB7551 Anybus X-gateway DeviceNet Master - IIoT AB7553 Anybus X-gateway Ethernet/IP Master - IIoT AB7554 Anybus X-gateway Ethernet/IP Slave - IIoT AB7555 Anybus X-gateway Modbus TCP Slave - IIoT AB7556 Anybus X-gateway IIoT-EtherCAT Slave AB7557 Anybus X-gateway CC-Link IE Field Slave - IIoT AB7558 Anybus X-gateway IIoT-PROFIBUS DP-V0 Slave AB7559 Anybus X-gateway IIoT-DeviceNet Slave AB7560 Anybus X-gateway IIoT-CANopen Slave AB7561 Anybus X-gateway IIoT-Modbus RTU Slave AB7562 Anybus X-gateway IIoT-CC-Link Slave AB7564 Anybus X-gateway IIoT-ControlNet Slave AB7570 Anybus X-gateway IIoT-PROFINET IRT, CC-Link IE Field Network Slave EtherCAT Slave AB7963 Anybus X-gateway CC-Link IE Field Network Slave CANopen Slave AB7964 Anybus X-gateway CC-Link IE Field Network Slave Modbus-RTU Slave AB7985 Anybus X-gateway PROFIBUS DP-V0 Master- PROFINET IRT Fiber Optic Slave AB9071 Anybus PROFIBUS to .NET Bridge AB9077 Anybus PROFINET to .NET Bridge AB9078 Anybus Ethernet/IP to .NET Bridge AB9079 Anybus EtherCAT to .NET Bridge HMS-EN2MB-R EtherNet/IP to Modbus-TCP Linking Device HMS-EN2PB-R EtherNet/IP to PROFIBUS Linking Device HMS-EN2SE-R EtherNet/IP to Serial Linking Device

Document
User Manual - Anybus Communicator IIoT

Output Data (512 bytes) This area cannot be accessed by the IT network but can be used for setting static values on the subnetwork., Enabled but no startup lock Same as Enabled, but the Data Valid bit does not have to be set., The two values can be given as a Byte (8 bits), Word (16 bits) or DWord (32 bits), Data Object Parameters Parameter Description Byte Swap No swapping No swapping is performed on the data Swap 2 bytes A, B, C, D becomes B, A, D, C Swap 4 bytes A, B, C, D becomes D, C, B, A Data Length The length of the data block in bytes., A subnet mask is a 32- bit binary pattern, where a set bit allocates a bit for Network/Subnet ID, and a cleared bit allocates a bit for the Host ID.