Filter

Loading...
Loading...
Loading...
40 results
Product
Ixxat CAN cable
Item number: 1.04.0076.00180

1.04.0076.00180

Document
1.04.0089.00301_Remote_Debug

2 1 2.09.0000.00251 D-SUB9 Buchse / female 3 1 D-SUB9 Haube 4 2 m Kabel, 3-adrig, geschirmt, 0,14 mm², LIYCY, hellgrau 5 1 Beschriftungsschild Schrumpfschlauch weiss Alternativ: 2-4 1 1.04.0076.00180 CAN-Kabel, Buchse verwenden, Stecker abschneiden Polbild Stecker A –Binder– Stecker B –D-Sub 9– Adernfarbe bei Verwendung von LIYCY Adernfarbe bei Verwendung von 1.04.0076.00180 2 2 weis braun 3 3 braun rot 6 5 grün gelb • ROHS – Konform • Elektr. geprüft • Verpackt jeweils 1 Stück in 1 ESD-gerechten Polybeutel REMOTE / DEBUG 1.04.0089.00301

Document
CAN-CR220 Datasheet 1.01.0067.44300 (English)

C A N p ropagation delay (typical) Typ. 175 ns (35 m bus length) Power supply +9 V to +32 V DC Power consumption at 24 V Typ. 41 mA, max. 100 mA Operating temperature -20 °C to +70 °C Weight Approx. 300 g Dimensions 22.5 x 100 x 118 mm Storage temperature -40 °C to +85 °C Protection class IP30 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC Housing material Polyamid CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-09 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N 1 2 3 4 + 9 V t o + 3 2 V D C 0 V - - P O W E R C O N N E C T O R 3 P i n n o .

Document
CAN-CR210 FO Datasheet 1.01.0068.46010 (English)

line length) Maximal line length between two FO repeaters 50/125 µm: 1500 m; 62.5/125 µm: 2000 m Power supply +9 V to +32 V DC Power consumption at 24 V Typ. 62 mA, max. 100 mA Operating temperature -20 °C to +70 ºC Weight Approx. 300 g Dimensions 22.5 x 100 x 120 mm Storage temperature -40 °C to +85 °C Protection class IP30 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC Housing material Polyamid CERTIFICAT ES ACCESSORIES ORDER NUMBER T bus connector 1.04.0073.00000 Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-09 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N 1 4 5 4 T ECHNICAL DRAWING

Document
USB-to-CAN V2 Family Datasheet (English)

USB-TO-CAN V2 AUTOMOTIVE ORDER NUMBER 1.01.0281.12001 1.01.0282.12001 1.01.0283.22002 1.01.0283.22042 Flash 512 kByte Power supply +5 V DC/300 mA (via USB port) Power consumption 48 mA-max. 300 mA Dimensions 80 x 50 x 22 mm 67 x 40 x 18 mm 80 x 50 x 22 mm 80 x 50 x 22 mm Weight Approx. 100 g Operating temperature -20 °C to +70 °C Storage temperature -40 °C to +85 °C Protection class IP40 None IP40 IP40 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC, UKCA Housing material ABS plastic - ABS plastic ABS plastic LED Two LEDs for CAN 1 and USB communication None Three LEDs for CAN 1, CAN 2 and USB communication Five LEDs for CAN 1, CAN 2, CAN LS, LIN and USB communication Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub male to female) 1.04.0075.03000 CAN cable 2.0 m (D-Sub male to female) 1.04.0076.00180

Document
CAN-IB100 PCIe 1.01.0231.12001 Datasheet (English)

CAN propagation delay (typical) With galvanic isolation typical 6 ns, max. 10 ns PC bus interface PCI express (V1.1), single lane port (x1) PC addess range/interrupts Plug & Play Power supply 3.3 V DC (via PCIe socket) Power consumption Typ. 350 mA Dimensions 64 x 105 mm Weight Approx. 55 g Operating temperature 0 °C to +70 °C Storage temperature -40 °C to +85 °C Relative humidity 10 % to 95 %, non-condensing Certification CE, FCC Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-08 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N P i n n o .

Document
CAN cable 2.0 m 1.04.0076.00180 Datasheet (English)

CAN cable 2.0 m 1.04.0076.00180 Datasheet (English)

Document
CAN@net NT 100 Datasheet 1.01.0332.10000 (English)

Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-08 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N 4 T ECHNICAL DRAWING CONNECTORS 1 = CAN (D-Sub 9) 2 = Ethernet (RJ45) 3 = Mini-USB 4 = POWER 1 2 3 4 SOFTWARE SUPPORT Configuration The configuration of the CAN@net NT and the firmware upload is done with an intuitive to operate Windows configuration tool via USB or Ethernet.

Document
USB-to-CAN V2 compact 1.01.0281.11001 Datasheet (English)

connection up to 1 Mbit/s with 9-pin D-Sub plug ■ Common driver interface for easy exchange of the PC interface type ■ Powerful programming interface for Windows (VCI) as well as for Linux (socketCAN or ECI), QNX and VxWorks (ECI) ■ DATA S H E E T U S B - to-CAN V2 compact V24-03 www.ixxat.com Page 2 of 3 ORDER NUMBER 1.01.0281.11001 Flash 512 kByte Power supply +5 V DC/300 mA (via USB port) Power consumption 48 mA-max. 300 mA Dimensions 80 x 50 x 22 mm Weight Approx. 100 g Operating temperature -20 °C to +70 °C Storage temperature -40 °C to +85 °C Protection class IP40 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC, UKCA Housing material ABS plastic LED 2 x LEDs for CAN and USB communication Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180

Document
CANnector LE 1.01.0091.00110 Datasheet (English)

USB interface 1 x Mini USB device interface, 2 x USB 2.0 host interface (480 Mbit/s) USB connector 1 x Mini USB, 2 x USB Type-A USB 2.0 host 2 Host system Power PC, 256 MByte RAM, 256 MByte Flash Power supply 6 to 36 V DC (via WPG connector) Power consumption 420 mA (12 V DC), sleep mode: 7.5 mA (12 V DC) Weight Approx. 790 g Housing material Aluminum, stainless steel Dimensions 196 x 113 x 43 mm Operating temperature -40 °C to +80 °C Storage temperature -40 °C to +85 °C Protection class IP40 Relative humidity 10-95 %, non-condensing LED 8 x LEDs, of which 7 are freely configurable Certification CE CERTIFICAT ES ACCESSORIES ORDER NUMBER Power cable for CANnector 1.04.0089.00002 CAN/LIN/K-Line Breakout Cable (1.5 m) 1.04.0089.00200 Double CAN Cable 1.04.0089.00201 USB WiFi Extension 1.04.0143.00000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 V24-05 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N Field Bus Interfaces EtherCAT Interfaces (only

Document
CANcheck Manual English

USB USB cable with A connector and B connector; length: 2 m 2.09.0000.01605 CAN CAN cable (1-to-1 cable) with SUB-D9 socket and SUB-D9 connector; length 2 m 1.04.0076.00180 CAN CAN cable (Y cable) with 2 x SUB-D9 socket and 1 x SUB-D9 connector; length 2 m 1.04.0076.00002 Trigger output CAN / trigger cable with SUB-D9-socket and SUB-D9 connector; trigger output routed out from the SUB-D9 socket onto a BNC connector; length 1 m 1.04.0076.00003 Appendix 82 CANcheck Manual, Version 2.3 11.4 Information on the Use of CANcheck CANcheck may cause fault or destruction of CAN nodes and systems controlled by them.

Document
CAN@net NT 200 Datasheet 1.01.0332.20000 (English)

Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-08 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N 1 2 3 4 1 2 3 4 V + ( + 9 V t o + 3 6 V D C ) V- - C A N - H i g h C A N - L o w C A N - G N D S h i e l d P O W E R C O N N E C T O R C A N C O N N E C T O R S 1 2 - 5 T ECHNICAL DRAWING 1 2 3 CONNECTORS 1 = CAN 1 2 = CAN 2 3 = Ethernet (RJ45) 4 = Mini-USB 5 = POWER 22,5 mm 107 mm 9 9 m m 114,5 mm 4 5 SOFTWARE SUPPORT Configuration The configuration of the CAN@net NT and the firmware upload is done with an intuitive to operate Windows configuration tool via USB or Ethernet.

Document
USB-to-CAN V2 compact 1.01.0281.12001 Datasheet (English)

plug ■ Common driver interface for easy exchange of the PC interface type ■ Powerful programming interface for Windows (VCI) as well as for Linux (socketCAN or ECI), QNX and VxWorks (ECI) ■ DATA S H E E T U S B - to-CAN V2 compact V24-03 www.ixxat.com Page 2 of 3 ORDER NUMBER 1.01.0281.12001 Microcontroller 32 Bit RAM 192 kByte Flash 512 kByte Power supply +5 V DC/300 mA (via USB port) Power consumption 48 mA-max. 300 mA Dimensions 80 x 50 x 22 mm Weight Approx. 100 g Operating temperature -20 °C to +70 °C Storage temperature -40 °C to +85 °C Protection class IP40 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC, UKCA Housing material ABS plastic LED 2 x LEDs for CAN and USB communication Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180

Document
simplyCAN Datasheet 1.01.0001.12001 (English)

20 °C to +70 °C Storage temperature -40 °C to +85 °C Protection class IP40 Inexpensive and easy to install – no driver installation required ■ Galvanic isolation ■ Compatible with USB 1.1, USB 2.0, and USB 3.x ■ Simple API interface for fast integration into customer applications ■ Optimized for diagnosis and commissioning of devices and systems with CAN bus interface ■ DATA S H E E T s i m p l y C A N V1.0 www.ixxat.com Page 2 of 3 ORDER NUMBER 1.01.0001.12001 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC Housing material ABS plastic LED Two LEDs for CAN and USB communication Operating Systems simplyCAN is tested on Windows 7 (32 bit and 64 bit) and Windows 10 (64 bit), Ubuntu 14.04 on Linux kernel version 4.4 as well as Ubuntu 18.04 on Linux kernel version 4.15 on Intel/AMD proc CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub male to female) 1.04.0075.03000 CAN cable 2.0 m (D-Sub male to female) 1.04.0076.00180

Document
USB-to-CAN V2 Plugin Family Datasheet (English)

USB interface USB 2.0 hi-speed (480 Mbit/s), compatible with USB 1.1 and USB 3.x USB connector Single row female header; 2.54 pitch Microcontroller 32 Bit RAM 136 kByte Flash 512 kByte Power supply +5 V DC/300 mA (via USB port) Power consumption Max. 300 mA Dimensions 67.5 x 40 x 9.2 mm Weight Approx. 15 g Operating temperature -40 °C to +85 °C Storage temperature -40 °C to +85 °C Relative humidity 10 to 95 %, non-condensing Certification CE, FCC, UKCA LED 2 x LEDs for CAN and USB communication 2 x LEDs for CAN and USB communication 3 x LEDs for CAN 1, CAN 2 and USB communication Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-03 www.ixxat.com Page 3 of 3

Document
CANnector LA 1.01.0091.00011 Datasheet (English)

CERTIFICAT ES ACCESSORIES ORDER NUMBER Power cable for CANnector 1.04.0089.00002 CAN/LIN/K-Line Breakout Cable (1.5 m) 1.04.0089.00200 Double CAN Cable 1.04.0089.00201 USB WiFi Extension 1.04.0143.00000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 V24-05 www.hms-networks.com/ixxat Page 3 of 3 PIN ALLOCAT I O N Field Bus Interfaces EtherCAT Interfaces (only selected variants) T ECHNICAL DRAWING SOFTWARE SUPPORT The CANnector provides various possibilities to manage configurations.

Document
USB-to-CAN V2 Plugin 1.01.0288.11003 Datasheet (English)

compatible with USB 1.1 and USB 3.x ■ 1 x high-speed CAN connection up to 1 Mbit/s ■ Galvanic isolation ■ Common driver interface for easy exchange of the PC interface type ■ Powerful programming interface for Windows (VCI) as well as for Linux (socketCAN or ECI), QNX and VxWorks (ECI) ■ DATA S H E E T U S B - to-CAN V2 Plugin V24-03 www.ixxat.com Page 2 of 3 ORDER NUMBER 1.01.0288.11003 Flash 512 kByte Power supply +5 V DC/300 mA (via USB port) Power consumption Max. 300 mA Dimensions 67.5 x 40 x 9.2 mm Weight Approx. 15 g Operating temperature -40 °C to +85 °C Storage temperature -40 °C to +85 °C Relative humidity 10 to 95 %, non-condensing Certification CE, FCC, UKCA LED 2 x LEDs for CAN and USB communication Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180

Document
USB-to-CAN V2 embedded 1.01.0282.12001 Datasheet (English)

Microcontroller 32 Bit RAM 192 kByte Flash 512 kByte Power supply +5 V DC/300 mA (via USB port) Power consumption 48 mA-max. 300 mA Dimensions 67 x 40 x 18 mm Weight Approx. 100 g Operating temperature -20 °C to +70 °C Storage temperature -40 °C to +85 °C Protection class IP40 Relative humidity 10 to 95 %, non-condensing Certification CE, FCC, UKCA Housing material - LED - Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180 CAN Y cable 0.22 m 1.04.0076.00001 CAN Y cable 2.1 m 1.04.0076.00002 V24-03 www.ixxat.com Page 3 of 3 PIN ALLOCAT I O N T ECHNICAL DRAWING 67 mm 325mm 18 mm 4 0 m m SOFTWARE SUPPORT Drivers and programming interfaces Comprehensive and powerful driver and software packages for the USB-to-CAN V2 series are available for free

Document
CAN-IB120/PCIe Mini Datasheet 1.01.0237.21000 (English)

temperature -40 °C to +85 °C Storage temperature -40 °C to +85 °C Relative humidity 10 % to 95 %, non-condensing Certification CE, FCC Cost-effective, passive CAN interface card for PCI Express Mini ■ Extremely compact design ■ 2 x CAN high-speed channels ■ Single Lane (x1) PCI Express Interface ■ Common driver interface for easy exchange of the PC interface type ■ Powerful programming interface for Windows (VCI) as well as for Linux (socketCAN or ECI), QNX and VxWorks (ECI) ■ DATA S H E E T C A N - I B 1 2 0 / P C I e M i n i V24-09 www.hms-networks.com/ixxat Page 2 of 3 ORDER NUMBER 1.01.0237.21000 Operating systems Windows 11, Windows 10 (32/64), Windows 8 (32/64), Windows 7 (32/64), Linux Additional information CAN socket aligned to the end of the card (back entry), also available as top entry version CERTIFICAT ES ACCESSORIES ORDER NUMBER Te r m i n ation adapter for CAN/CAN FD (D-Sub plug to socket) 1.04.0075.03000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180

Document
CANnector L 1.01.0091.00010 Datasheet (English)

channels 2 Ethernet interfaces 1 Ethernet connector 3 x RJ45 (1 x Ethernet 10/100 Base-T, 2 x f i e l d b u s ) EtherCAT (slave) - USB interface 1 x Mini USB device interface, 2 x USB 2.0 host interface (480 Mbit/s) USB connector 1 x Mini USB, 2 x USB Type-A USB 2.0 host 2 Host system Power PC, 256 MByte RAM, 256 MByte Flash Power supply 6 to 36 V DC (via WPG connector) Power consumption 420 mA (12 V DC), sleep mode: 7.5 mA (12 V DC) Weight Approx. 790 g Housing material Aluminum, stainless steel Dimensions 196 x 113 x 43 mm Operating temperature -40 °C to +80 °C Storage temperature -40 °C to +85 °C Protection class IP40 Relative humidity 10-95 %, non-condensing LED 8 x LEDs, of which 7 are freely configurable Certification CE CERTIFICAT ES ACCESSORIES ORDER NUMBER Power cable for CANnector 1.04.0089.00002 CAN/LIN/K-Line Breakout Cable (1.5 m) 1.04.0089.00200 Double CAN Cable 1.04.0089.00201 USB WiFi Extension 1.04.0143.00000 CAN cable 2.0 m (D-Sub plug to socket) 1.04.0076.00180