Filter

Loading...
Loading...
Loading...
19 results
Product
Toshiba VRF and Digital systems to Home Automation Interface
Item number: INWMPTOS001R000

INWMPTOS001R000, Toshiba VRF and Digital systems to Home Automation Interface INWMPTOS001R000 The Toshiba gateway allows complete and natural integration of Toshiba VRF and Digital systems into IP-based Home Automation Systems.

Document
User Manual

ORDER CODE LEGACY ORDER CODE INWMPDAI001I000 DK-AC-WMP-1 (IBWMPDAI001I000) INWMPDAI001R000 DK-RC-WMP-1 (IBWMPDAI001R000) INWMPFGL001I000 FJ-AC-WMP-1 (IBWMPFGL001I000) INWMPFGL001R000 FJ-RC-WMP-1 (IBWMPFGL001R000) INWMPMHI001I000 MH-AC-WMP-1 (IBWMPMHI001I000) INWMPMHI001R000 MH-RC-WMP-1 (IBWMPMHI001R000) INWMPMIT001I000 ME-AC-WMP-1 (IBWMPMIT001I000) INWMPPAN001I000 PA-AC-WMP-1 (IBWMPPAN001I000) INWMPPAN001R000 PA-RC2-WMP-1(IBWMPPAN001R000) INWMPLGE001R000 LG-RC-WMP-1 (IBWMPLGE001R000) INWMPTOS001R000 TO-RC-WMP-1 (IBWMPTOS001R000) INWMPUNI001I000 IS-IR-WMP-1 (IBWMPUNI001I000) Intesis TM WiFi series configuration User Manual v2.2 EN © HMS Industrial Networks S.L.U - All rights reserved This information is subject to change without notice https://www.hms-networks.com/intesis 4 / 19 WiFi series configuration manual 1., Installation For the product installation, consult the installation guide: Daikin AC Residential units: INWMPDAI001I000 Daikin VRV and Sky systems: INWMPDAI001R000 Fujitsu RAC and VRF systems (connection via the CN connector): INWMPFGL001I000 Fujitsu RAC and VRF systems (connection via the RC bus): INWMPFGL001R000 Mitsubishi Heavy Industries Residential units: INWMPMHI001I000 Mitsubishi Heavy Industries FD and VRF systems: INWMPMHI001R000 Mitsubishi Electric Domestic, Mr.Slim and City Multi systems: INWMPMIT001I000 Panasonic Etherea systems: INWMPPAN001I000 Panasonic ECOi and PACi systems: INWMPPAN001R000 LG VRF systems: INWMPLGE001R000 Toshiba VRF and Digital systems: INWMPTOS001R000 Universal IR Air Conditioner: INWMPUNI001I000 IMPORTANT The gateway must be installed in a secure location, such as a locked electrical cabinet or an area that is physically inaccessible.

Kb
What is the difference between 1 to 1 Home Automation (WMP) and AC Cloud Control Devices?

APPLICABLE PRODUCTS  Intesis AC Cloud Control: INWFIDAI001I000, INWFIDAI001R100, INWFIFGL001I000, INWFIFGL001R100, INWFILGE001R100, INWFIMHI001I000, INWFIMHI001R100, INWFIPAN001R100, INWFIPAN001I000, INWFITOS001R100, INWFIUNI001I000 Intesis 1 to 1 Home Automation: INWMPDAI001I000, INWMPDAI001R000, INWMPFGL001I000, INWMPFGL001R000, INWMPLGE001R000, INWMPMIT001I000, INWMPMHI001I000, INWMPMHI001R000, INWMPPAN001R000, INWMPPAN001I000, INWMPTOS001R000, INWMPUNI001I000   QUESTION What is the difference between AC Cloud Control and Home Automation if they use the same hardware?  

Document
Datasheet

 Intesis INWMPTOS001R000 Datasheet r1.1 EN © HMS Industrial Networks S.L.U - All rights reserved This information is subject to change without notice URL https://www.intesis.com 1 / 3 INWMPTOS001R000 TO-RC-WMP-1 Wi-Fi interface for Toshiba VRF and Digital lines 1., Introduction Intesis INWMPTOS001R000 (TO-RC-WMP-1) allows a complete and natural integration of Toshiba Air Conditioners into IP based control systems., Dimensions Figure 2.1 Device dimensions in mm and back view with fixing holes Intesis INWMPTOS001R000 Datasheet r1.1 EN © HMS Industrial Networks S.L.U - All rights reserved This information is subject to change without notice URL https://www.intesis.com 2 / 3 3.

Document
User Manual inwmpxxx001xx00 DE

BESTELLNUMMER ALTE BESTELLNUMMER INWMPDAI001I000 DK-AC-WMP-1 (IBWMPDAI001I000) INWMPDAI001R000 DK-RC-WMP-1 (IBWMPDAI001R000) INWMPFGL001I000 FJ-AC-WMP-1 (IBWMPFGL001I000) INWMPFGL001R000 FJ-RC-WMP-1 (IBWMPFGL001R000) INWMPMHI001I000 MH-AC-WMP-1 (IBWMPMHI001I000) INWMPMHI001R000 MH-RC-WMP-1 (IBWMPMHI001R000) INWMPMIT001I000 ME-AC-WMP-1 (IBWMPMIT001I000) INWMPPAN001I000 PA-AC-WMP-1 (IBWMPPAN001I000) INWMPPAN001R000 PA-RC2-WMP-1(IBWMPPAN001R000) INWMPLGE001R000 LG-RC-WMP-1 (IBWMPLGE001R000) INWMPTOS001R000 TO-RC-WMP-1 (IBWMPTOS001R000) INWMPUNI001I000 IS-IR-WMP-1 (IBWMPUNI001I000) Konfiguration der Intesis TM WiFi-Serie Benutzerhandbuch r2.1 EN © HMS Industrial Networks S.L.U - Alle Rechte vorbehalten Änderungen ohne weitere Ankündigung vorbehalten URL https://www.intesis.com 4 / 19 Konfigurationshandbuch der WiFi-Serie 1.

Document
testing upload

AC Domestic units to Home Automation RAC and VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation FD and VRF systems to Home Automation Etherea AC units to Home Automation VRV and Sky systems to Home Automation Domestic units to Home Automation ECOi and PACi systems to Home Automation INWMPDAI001I000 ORDER CODE INWMPFGL001R000 INMBSFGL016O000 INWMPFGL001I000 INWMPLGE001R000 INWMPMHI001R000 INWMPPAN001I000 INWMPMIT001I000 INWMPTOS001R000 INWMPUNI001I000 INWMPDAI001R000 INWMPMHI001I000 INWMPPAN001R000 1 I.U.

Document
INBREN2020_Intesis Brochure_01-2020_Final revision_v2_DE_Web

Slim und City Multi zu WLAN (ASCII) VRF- und digitale Systeme zu WLAN (ASCII) Universelle IR-Klimaanlage zu WLAN (ASCII) VRV- und Sky-Systeme zu WLAN (ASCII) Haushalts-Klimagerät zu WLAN (ASCII) ECOi- und PACi-Systeme zu WLAN (ASCII) INWMPDAI001I000 ORDER CODE INWMPFGL001R000 INWMPFGL001I000 INWMPLGE001R000 INWMPMHI001R000 INWMPPAN001I000 INWMPMIT001I000 INWMPTOS001R000 INWMPUNI001I000 INWMPDAI001R000 INWMPMHI001I000 INWMPPAN001R000 1 Innengerät POINT VERSION 1 Innengerät (an Fernsteuerung) 1 Innengerät (an CN-Anschluss) 1 Innengerät 1 Innengerät 1 Innengerät 1 Innengerät 1 Innengerät 1 Innengerät 1 Innengerät 1 Innengerät 1 Innengerät UNIVERSELL www. i ntesis.com HMS ist Ihr Partner für industrielle Kommunikation und IIoT.

Document
order codes_wifi_multiprotocol (do not use)

Slim and City Mul� (RAC, PAC, VRF) MH-RC-WMP-1 IBWMPMHI001R000 INWMPMHI001R000 Wi-Fi - MITSUBISHI HEAVY INDUSTRIES AC FD, KX6, KXR6 Series (RAC, PAC,VRF) PA-AC-WMP-1 IBWMPPAN001I000 INWMPPAN001I000 Wi-Fi - PANASONIC AC Domes�c Lines (RAC) PA-RC2-WMP-1 IBWMPPAN001R000 INWMPPAN001R000 Wi-Fi - PANASONIC AC ECOi & PACi lines (PAC, VRF) TO-RC-WMP-1 IBWMPTOS001R000 INWMPTOS001R000 Wi-Fi - TOSHIBA AC Commercial & VRF Lines (PAC, VRF) Wifi Multi Protocol (WMP) Series Gateways

Document
CE Declaration of Conformity

Address: Milà i Fontanals, 7 08700 Igualada SPAIN Product: Type: Control unit (WIFI Air Conditioner Controller) IS-RC2-WIFI-1-V2 Order Code(s): INWMPPAN001R000 INWMPTOS001R000 INWFIPAN001R000 INWFITOS001R000 The products are in accordance with the following Directives Number: 2014/35/EU Directive 2014/35/EC of the European Parliament and the Council of 26 February 2014 on the harmonization of the Laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits and have been designed and manufactured applying the following harmonized standards: EN 62368-1:2014 + A11: 2017 + AC:2017 Audio/video, information and communication technology equipment - Part 1: Safety requirements.

Document
Home Automation Intesis MP

Automation RAC and VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation Commercial & VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation Domestic units to Home Automation Etherea AC units to Home Automation Domestic, Mr.Slim and City Multi to Home Automation City Multi systems to Home Automation VRF and Digital systems to Home Automation NASA VRF systems to Home Automation Universal IR Air Conditioner to Home Automation VRV and Sky systems to Home Automation FD and VRF systems to Home Automation ECOi and PACi systems to Home Automation ECOi, ECOg and PACi systems to Home Automation ECOi, ECOg and PACi systems to Home Automation INWMPDAI001I000 ORDER CODE INWMPFGL001I000 IN770AIR00*O000 IN770AIR00*O000 IN776MHI00*O000 IN770AIR00*O000 INMBSFGL016O000 INWMPFGL001R000 INWMPLGE001R000 INWMPMHI001I000 INWMPPAN001I000 INWMPMIT001I000 IN770AIR00*O000 INWMPTOS001R000

Kb
How can I check if my wired remote control is compatible with Intesis solutions?

APPLICABLE PRODUCTS  RC Brand Specific Solutions: (INBACDAI001R000, IN485DAI001R000, INBACHIT001R000, IN485HIT001R000, INBACMHI001R000, IN485MHI001R000, INBACPAN001R000, INBACPAN001R100, INBACSAM001R100, INBACTOS001R000, INBACTOS001R100, INKNXDAI001R000, INKNXDAI001R100, INKNXFGL001R000, INKNXHIS001R000, INKNXHIT001R000, INKNXLGE001R000,INKNXMHI001R000, INKNXPAN001R000, INKNXTOS001R000, INMBSDAI001R000, INMBSFGL001R000, INMBSHIS001R000, INMBSHIT001R000, INMBSLGE001R000, INMBSMHI001R000, INMBSPAN001R000, INMBSSAM001R100, INMBSSAM001R000, INMBSTOS001R000, INWMPDAI001R000, INWMPFGL001R000, INWMPLGE001R000, INWMPMHI001R000, INWMPPAN001R000, INWMPTOS001R000, INWFIDAI001R100, INWFIFGL001R100, INWFILGE001R100, INWFIMHI001R100, INWFIPAN001R100, INWFITOS001R100)   QUESTION How to check if my wired remote control with Intesis products?  

Kb
Toshiba Compatibilitites

APPLICABLE PRODUCTS Toshiba & Universal AC Interfaces: (INWFITOS001R100, INBACTOS001R000, INBACTOS001R100, INWMPTOS001R000, INKNXTOS001R000, INMBSTOS001R000, INKNXTOS016O000, INKNXTOS064O000, INWFIUNI001I000, IN485UNI001I100, INWMPUNI001I000, INKNXUNI001I000).  

Document
Installation Guide

 INWMPTOS001R000 Gateway Installation Guide © HMS Industrial Networks S.L.U - All rights reserved This information is subject to change without notice https://www.hms-networks.com/intesis Version 1.1 1 / 2 Toshiba VRF and Digital Systems to Home Automation Gateway WARNING Follow these instructions carefully., Safety instructions Installation instructions INWMPTOS001R000 Gateway Installation Guide © HMS Industrial Networks S.L.U - All rights reserved This information is subject to change without notice https://www.hms-networks.com/intesis Version 1.1 2 / 2 IMPORTANT NOTE: If a wired remote controller is connected to the same bus, communication between the indoor unit and the gateway may be interrupted.

Kb
How to check if my climatization system is compatible with Intesis products?

AC Interfaces & AC Cloud Control - RC (IN485HIT001R000, INBACHIT001R000, IN485DAI001R000, INBACDAI001R000, INBACPAN001R100, INBACPAN001R000, INBACSAM001R100, INBACMHI001R100, INBACMHI001R000, IN485MIT001I000, INBACMIT001I000, INBACTOS001R100, INBACTOS001R000, INMBSTOS001R000, INMBSSAM001R000, INMBSSAM001R100, INMBSPAN001R000, INMBSMHI001R000, INMBSLGE001R000, INMBSHIT001R000, INMBSHIS001R000, INMBSFGL001R000, INMBSDAI001R000, INKNXTOS001R000, INKNXPAN001R000, INKNXMHI001R000, INKNXLGE001R000, INKNXHIT001R000, INKNXHIS001R000, INKNXFGL001R000, INKNXDAI001R100, INKNXDAI001R000, INWMPTOS001R000, INWMPPAN001R000, INWMPMHI001R000, INWMPLGE001R000, INWMPFGL001R000, INWMPDAI001R000, INWFITOS001R100, INWFIPAN001R100, INWFIMHI001R100, INWFILGE001R100, INWFIFGL001R100, INWFIDAI001R100).

Document
INBR-JP-GE_Intesis Brochure_01-2023_WEB

D r i vers available Home Controller or Smart Hub Universal IR Brand specific RC Brand specific AC Wired remote controller (optional) Drivers available Home Controller or Smart Hub 住宅用エアコンユニットをホームオートメーションに接続 VRFおよびSkyシステムをホームオートメーションに接続 型式 1台室内機接続 接続可能ユニット数 (台室内機接続) 1台室内機接続 INWMPDAI001I000 INWMPDAI001R000 RACおよびVRFシステムをホームオートメーションに接続 VRFシステムをホームオートメーションに接続 16台室内機接続 1台室内機接続(CNコネクタに接続) 1台室内機接続(リモートコントローラーに接続) INWMPFGL001R000 INMBSFGL016O000 INWMPFGL001I000 VRFシステムをホームオートメーションに接続 1台室内機接続 INWMPLGE001R000 業務用およびVRFシステムをホームオートメーションに接続 se r i e s IN770AIR00*O000 16&64台室内機接続 1台室内機接続 VRFおよびデジタルシステムをホームオートメーションに接続 INWMPTOS001R000 1台室内機接続 UNIVERSAL Universal IRエアコンをホームオートメーションに接続 INWMPUNI001I000 VRFシステムをホームオートメーションに接続 IN770AIR00*O000 16&64台室内機接続 se r i e s VRFシステムをホームオートメーションに接続 IN770AIR00*O000 16&64台室内機接続 se r i e s 1台室内機接続 住宅用システム、 M r.Slim、 C i t y M u l t iをホームオートメーションに接続 住宅用システム、 M r.Slim、 C i t y M u l t iをホームオートメーションに接続 INWMPMIT001I000

Document
Intesis Brochure

Drivers available Drivers available Home Controller or Smart Hub Home Controller or Smart Hub Domestic, Commercial and VRF single units Universal IR Brand specific RC Brand specific AC Wired remote controller (optional) VRF systems 25 24 AC Domestic units to Home Automation RAC and VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation FD and VRF systems to Home Automation Etherea AC units to Home Automation VRV and Sky systems to Home Automation Domestic units to Home Automation VRF systems to Home Automation ECOi and PACi systems to Home Automation INWMPDAI001I000 INWMPFGL001R000 IN775FGL***O000 INWMPFGL001I000 INWMPLGE001R000 INWMPMHI001R000 INWMPPAN001I000 INWMPMIT001I000 INWMPTOS001R000 INWMPUNI001I000 INWMPDAI001R000 INWMPMHI001I000 IN776MHI***O000 INWMPPAN001R000 1 I.U. 1 I.U.

Document
AC Interfaces - Intesis Brochure

Drivers available Drivers available Home Controller or Smart Hub Home Controller or Smart Hub Domestic, Commercial and VRF single units Universal IR Brand specific RC Brand specific AC Wired remote controller (optional) VRF systems 19 AC Domestic units to Home Automation RAC and VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation FD and VRF systems to Home Automation Etherea AC units to Home Automation VRV and Sky systems to Home Automation Domestic units to Home Automation VRF systems to Home Automation ECOi and PACi systems to Home Automation INWMPDAI001I000 INWMPFGL001R000 IN775FGL***O000 INWMPFGL001I000 INWMPLGE001R000 INWMPMHI001R000 INWMPPAN001I000 INWMPMIT001I000 INWMPTOS001R000 INWMPUNI001I000 INWMPDAI001R000 INWMPMHI001I000 IN776MHI***O000 INWMPPAN001R000 1 I.U. 1 I.U.

Document
Protocol Translators - Intesis Brochure

Drivers available Drivers available Home Controller or Smart Hub Home Controller or Smart Hub Domestic, Commercial and VRF single units Universal IR Brand specific RC Brand specific AC Wired remote controller (optional) VRF systems 25 AC Domestic units to Home Automation RAC and VRF systems to Home Automation VRF systems to Home Automation VRF systems to Home Automation FD and VRF systems to Home Automation Etherea AC units to Home Automation VRV and Sky systems to Home Automation Domestic units to Home Automation VRF systems to Home Automation ECOi and PACi systems to Home Automation INWMPDAI001I000 INWMPFGL001R000 IN775FGL***O000 INWMPFGL001I000 INWMPLGE001R000 INWMPMHI001R000 INWMPPAN001I000 INWMPMIT001I000 INWMPTOS001R000 INWMPUNI001I000 INWMPDAI001R000 INWMPMHI001I000 IN776MHI***O000 INWMPPAN001R000 1 I.U. 1 I.U.

Document
Intesis HVAC gateways for Toshiba

., 1 Binary Input Connect to: A/B INBACTOS001R000 INBACTOS001R100 INKNXTOS001R000 INKNXTOS***O000 INMBSTOS001R000 Connect to: A/B BACnet MS/TP or IP Connect to: A/B BACnet MS/TP or IP Connect to: A/B Connect to: TCC- LINK Connect to: A/B 1 Indoor Unit 1 Indoor Unit 1 I.U. 4 Binary Input 16/64 Indoor Units 1 Indoor Unit INWMPTOS001R000 Connect to: A/B 1 Indoor Unit INWFITOS001R100 1 Indoor Unit Owned by HMS Industrial Networks, Intesis® is a registered trademark in the European Union and is trademarked in the rest of the world., Learn more at www.hms-networks.com/intesis Connection to the To s h i b a i n d o o r u n i t s 21 I n d o o r u n i t IN485UNI001I100 INKNXUNI001I000 INWMPUNI001I000 INWFIUNI001I000 C o n n e c tion to the To s h i b a w i red remote controller bus Connection to the To s h i b a O u tdoor Units Connection to A/B Indoor unit INBACTOS001R000 INBACTOS001R100 INKNXTOS001R000 INMBSTOS001R000 INWMPTOS001R000 INWFITOS001R100 Indoor units Outdoor Units Connection to TCC-LINK BUS INKNXTOS***O000 Owned by HMS Industrial Networks, Intesis® is a registered trademark in the European Union and is trademarked in the rest of the world.